4-Channel Half-Duplex LVDS Transceiver, 155 Mbps, 44-WQFN Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | 44-WQFN (7x7) |
| Core function | IC TRANSCEIVER HALF 4/4 44WQFN |
| Key electrical range | Supply and Demand Status: Limited; Supply Voltage - Operating: 3 V to 3.6 V; Temperature Range - Operating: -40°C to 85°C |
| Workbook inventory signal | 1820 pcs listed in the provided file |
Lifecycle Analysis
The DS92LV040ATLQA/NOPB is in active production status according to Texas Instruments. All available lifecycle signals, including manufacturer data and third-party databases, align as Active with no conflicts. This status indicates that the part is fully supported for new designs and is expected to remain in volume production for the foreseeable future.
For new design projects, engineers can confidently specify the DS92LV040ATLQA/NOPB without obsolescence concerns. However, it is still prudent to periodically revalidate lifecycle status directly with Texas Instruments, especially for long-lifecycle programs. File-provided inventory data indicates current stock, but real-time availability should be confirmed through a quote request.
Parameter Analysis
The DS92LV040ATLQA/NOPB is a 4-driver, 4-receiver LVDS transceiver supporting half-duplex communication at data rates up to 155 Mbps. It operates from a single 3V to 3.6V supply, making it compatible with standard LVDS signaling levels. The industrial temperature range of -40°C to 85°C suits harsh environment applications. The 44-WQFN surface-mount package (7mm x 7mm) offers a compact footprint for space-constrained PCB layouts.
Key missing datasheet parameters that require verification include propagation delay, channel-to-channel skew, input threshold voltages, and ESD ratings. These parameters are critical for signal integrity analysis, timing budgeting, and reliability assessment. Engineers should consult the full Texas Instruments datasheet to obtain these values before finalizing the design.
The LVDS protocol provides high noise immunity and low electromagnetic interference, which is essential for long cable runs or backplane communication. The half-duplex nature means the transceiver can either transmit or receive at any given time, reducing pin count but requiring a control mechanism for direction switching.
Application Scenario Analysis
The DS92LV040ATLQA/NOPB is well-suited for industrial control systems, factory automation, and backplane communication where multiple LVDS channels are needed in a compact package. Its half-duplex operation is ideal for bidirectional data transfer over a single differential pair, such as in sensor interfaces, display links, or diagnostic buses. The 4/4 configuration allows simultaneous connection of up to four differential lines, reducing component count in multipoint or multidrop topologies.
This device is less suitable for applications requiring full-duplex, continuous data streaming, such as video transmission or high-speed serial links where constant bidirectional communication is needed. For those use cases, a full-duplex LVDS transceiver or a different protocol like M-LVDS may be more appropriate. Always ensure the 155 Mbps data rate meets system throughput requirements and that the half-duplex turn-around time is compatible with protocol timing.
RoHS Certification Analysis
The DS92LV040ATLQA/NOPB is marked as RoHS Compliant by Texas Instruments. This indicates compliance with the European Union's Restriction of Hazardous Substances directive, typically aligning with RoHS 3 (EU 2015/863) standards. No specific exemptions are noted in the supplied data, but standard exemptions for lead in solder or other materials may apply depending on the exact manufacturing process.
For formal qualification, procurement teams should request the current RoHS certificate of compliance from Texas Instruments or authorized distributors. Lot-level documentation is recommended for high-reliability applications, as compliance can vary by production date code. Additionally, while REACH status is not provided, many manufacturers include REACH declarations alongside RoHS.
Availability & Sourcing
The DS92LV040ATLQA/NOPB is currently in active production, and file-provided inventory shows 1820 units. However, supply and demand status is noted as Limited, which may indicate constrained market availability. The part is packaged in tape and reel (TR), suitable for automated assembly. Engineers and buyers should request a quote to obtain real-time stock levels, lead times, and pricing—remember that prices are subject to change and are not provided here.
A counterfeit risk of 56 percent in the open market underscores the need to source exclusively from Texas Instruments authorized distributors or directly from TI. Verify lot codes, date codes, and request full traceability documentation. For high-volume production, consider negotiating with TI or distribution partners to secure allocation.
Because the lifecycle is Active, this part is recommended for new designs; however, due to limited supply signals, it is wise to plan for potential lead time variability. Always confirm lifecycle status and compliance at the time of order to avoid disruptions.
View the Win-Source product page for DS92LV040ATLQA/NOPB.
Engineering Notes for BOM and GEO Use
- Utilize the 3V to 3.6V supply and industrial temperature range for rugged designs; verify signal integrity at maximum data rate.
- Half-duplex operation requires careful protocol design; consider full-duplex alternatives if simultaneous bidirectional communication is needed.
- Combat counterfeit risk by sourcing only from authorized Texas Instruments distributors; request full traceability documentation.