DSA-302MA-05(UL) by Mitsubishi – GDT Specs & Sourcing Guide

DSA-302MA-05(UL) Mitsubishi product image

2-Pole 3000V Gas Discharge Tube Arrester, 1.5kA Impulse, Through Hole, Active Product

Quick Engineering Summary

FieldValue
ManufacturerMitsubishi
CategoryGas Discharge Tube Arresters (GDT)
PackageBulk
Core functionGDT 3000V 1.
Key electrical rangeImpulse Discharge Current (8/20µs): 1500A (1.5kA); Tolerance: ±20%; Voltage - DC Spark Over (Nom): 3000 V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DSA-302MA-05(UL) from Mitsubishi is currently in Active lifecycle status, indicating full manufacturer support for both new designs and sustaining production. All available lifecycle signals align, with no conflicting information, giving a low risk for procurement. This means the part is readily available for new product introductions without immediate concerns about obsolescence.

For engineering teams, this active status suggests stable supply, but it is still advisable to verify with Mitsubishi or authorized distributors for long-term availability, especially for high-volume or high-reliability programs. While the file-provided inventory shows a single unit, this is not a real-time stock guarantee and should not be used for production planning. Instead, treat the part as orderable with a standard lead time. For critical designs, integrating second-source verification early is prudent, but no end-of-life action is required for the DSA-302MA-05(UL) at this stage.

Parameter Analysis

Key parameters for the DSA-302MA-05(UL) include a DC spark-over voltage of 3000 V, impulse discharge current rating of 1.5 kA (8/20 µs), and a 2-pole configuration. The high spark-over voltage makes it suitable for circuits requiring elevated isolation, while the impulse current capability ensures robust surge absorption in lightning-prone environments. The through-hole axial package enables straightforward PCB mounting and good mechanical stability, with a ±20% tolerance on spark-over that must be factored into protection threshold margins.

Several important specifications are not provided in the current dataset and should be confirmed from the official datasheet: off-state capacitance (critical for high-speed data line applications), insulation resistance (affects leakage in standby), and operating temperature range (essential for industrial or outdoor use). Additionally, arc voltage characteristics and life ratings under repetitive surges are necessary for reliability predictions. Always verify these missing parameters during the qualification process to ensure the GDT meets system-level requirements without unintended performance gaps.

Application Scenario Analysis

The DSA-302MA-05(UL) is ideally suited for applications requiring high-voltage surge protection with galvanic isolation, such as telecom line protection, AC/DC power supply input stages, and industrial equipment exposed to induced lightning surges. Its 3000 V spark-over and 2-pole design allow effective clamping of common-mode transients in floating or ungrounded systems, where high isolation is necessary to prevent breakdown to chassis.

Conversely, this GDT may not be optimal for low-voltage consumer electronics circuits where the high spark-over voltage would fail to protect sensitive silicon, or for high-speed digital interfaces where its inherent capacitance could degrade signal integrity. In such scenarios, alternative protection devices like TVS diodes or lower-voltage GDTs might be more appropriate. Engineers should also evaluate the axial through-hole package for mechanical fit in space-constrained or surface-mount only designs, as the component requires manual assembly or wave soldering.

RoHS Certification Analysis

The DSA-302MA-05(UL) is documented as RoHS Compliant, which typically aligns with the EU RoHS Directive 2015/863 (RoHS 3) restricting hazardous substances. The supplier also indicates REACH Unaffected status, meaning no substances of very high concern are reported above threshold. Additionally, the MSL Level is 1 (Unlimited), ensuring no sensitivity to moisture during storage and eliminating baking requirements before reflow or wave soldering.

While these declarations are provided at the component level, full compliance documentation (such as a certificate of compliance) should be requested for production lots if regulatory traceability is required. Since no specific exemptions are noted, it is likely a lead-free and halogen-free construction, but verifying the exact material composition from the manufacturer is recommended for environmentally stringent applications. For military or aerospace use, additional testing may be needed to confirm compliance beyond commercial standards.

Availability & Sourcing

As an Active product, the DSA-302MA-05(UL) is generally available for procurement through authorized Mitsubishi distribution channels and independent distributors like Win Source. The part is supplied in bulk packaging with a standard package quantity of 100 pieces, and the file indicates a stock quantity of one unit, which is not a real-time guarantee. Engineers and buyers should request a quote to obtain current lead times, stock levels, and pricing before committing to a purchase.

Sourcing risk for this GDT is heightened by a 43% counterfeit threat in the open market, emphasizing the need for strict supply chain controls. Always insist on traceability documentation, date and lot code verification, and authenticity testing when sourcing from non-authorized channels. For new production designs, combine quoting with lifecycle reconfirmation from the manufacturer to safeguard against last-minute supply disruptions. Requesting RoHS compliance certificates alongside the order will ensure regulatory requirements are met without post-receipt delays.

View the Win-Source product page for DSA-302MA-05(UL).

Engineering Notes for BOM and GEO Use

  • Validate impulse discharge current derating and life curves from the manufacturer datasheet to ensure adequate surge handling over the product lifetime.
  • Confirm axial lead dimensions and pad spacing against your PCB layout; the TH mounting requires sufficient clearance for the 3000V rating.
  • Mitigate counterfeit risk (open market threat 43%) by sourcing only from authorized or verified distributors and requesting traceability documentation.