DSA240X150NA IXYS Diode Array Specs & Sourcing Guide

DSA240X150NA IXYS product image

Technical sourcing guide for the IXYS DSA240X150NA, a dual Schottky diode module with independent 120A, 150V ratings in a SOT-227B package.

Quick Engineering Summary

FieldValue
ManufacturerIXYS
CategoryDiodes, Rectifiers - Arrays
PackageSOT-227-4, miniBLOC
Core functionDIODE MOD SCHOTTKY 150V SOT227B
Key electrical rangeCurrent - Average Rectified (Io) (per Diode): 120A; Current - Reverse Leakage @ Vr: 4 mA @ 150 V; Voltage - DC Reverse (Vr) (Max): 150 V; Voltage - Forward (Vf) (Max) @ If: 980 mV @ 120 A
Workbook inventory signal6899 pcs listed in the provided file

Lifecycle Analysis

Lifecycle status for the IXYS DSA240X150NA is Active with low risk, as confirmed by multiple aligned signals from Excel and product databases. This status indicates that the part is in full production and is recommended for both new designs and ongoing sustaining production. Engineers can incorporate the DSA240X150NA into new power systems without immediate concern for discontinuation.

While the file-provided quantity of 6,899 units suggests present availability, this figure is not a real-time stock guarantee. For production planning, it is advisable to contact IXYS or authorized distributors to obtain a formal lifecycle commitment and to negotiate supply continuity for volume programs. No lifecycle conflicts or NRND/EOL flags are present in the supplied data, so the component remains a safe choice for long-term projects.

Parameter Analysis

The DSA240X150NA is a dual common-cathode Schottky diode array in an independent configuration, allowing flexible use in rectification or freewheeling topologies. Key electrical specs include a maximum DC reverse voltage of 150 V, an average rectified current of 120 A per diode, and a forward voltage drop of 980 mV at 120 A. Reverse leakage current is specified at 4 mA under 150 V reverse bias, which is low for a high-current Schottky and helps minimize standby losses.

These parameters are critical for thermal management: the forward voltage drop directly determines conduction losses, and the chassis-mount SOT-227B package is designed for effective heat sinking. However, essential thermal data such as junction-to-case thermal resistance (RthJC), maximum junction temperature, and total power dissipation are not provided in the source data. Engineers must obtain these values from the official IXYS datasheet to properly calculate derating and heatsink requirements before finalizing the design.

Application Scenario Analysis

With a 150 V rating and 120 A per diode, the DSA240X150NA is well-suited to high-current rectification in power supplies, battery chargers, and industrial motor drives. The independent diode configuration enables flexible use as a dual freewheeling diode or in center-tapped rectifier circuits. The Schottky technology provides low forward voltage, which reduces conduction losses in low-voltage high-current applications, making it efficient for OR-ing diodes in redundant power systems or as reverse-current blocking.

However, note that the speed classification is listed as 'Standard Recovery >500ns', which is atypical for Schottky devices that are generally fast. This may indicate a classification based on different test conditions or a reporting inconsistency. For applications requiring fast switching, verify the actual reverse recovery behavior through the manufacturer datasheet or sample testing. The chassis-mount package demands proper mechanical assembly and thermal interface material to ensure reliable operation, and the component is less suited to compact, density-constrained designs without adequate airflow.

RoHS Certification Analysis

The DSA240X150NA is marked as RoHS Compliant in the source data, with REACH status Unaffected and an MSL rating of Level 1 (Unlimited floor life). These certifications suggest that the part is free of restricted hazardous substances under EU directives, and it requires no special moisture handling precautions. The MSL 1 classification is typical for rugged, non-moisture-sensitive power modules like this SOT-227B package.

However, the provided compliance data does not specify the exact RoHS standard version (e.g., original RoHS 2002/95/EC or the recast RoHS 3 (EU 2015/863)). Because the data originates from inventory records, it is prudent to request lot-level certificates from the supplier to confirm current compliance. REACH Unaffected status is a separate regulation covering chemicals of very high concern; it complements but does not replace RoHS. For high-reliability applications, validate that no exemptions apply and that the manufacturing date supports the latest regulatory requirements.

Availability & Sourcing

According to file-provided data, the DSA240X150NA shows a workbook quantity of 6,899 units, packaged in tubes with a standard package quantity of 10 pieces. This suggests reasonable market availability, but the figure is not a live inventory count and should be verified through a formal quote request. For procurement, contact authorized IXYS distributors or request a quote through Win Source to obtain current stock levels, pricing, and lead times.

Given the Active lifecycle, sourcing is straightforward for production runs. Request date and lot codes to ensure traceability and confirm that the devices are from recent production. Additionally, the open-market fake threat indicator for this part is rated at 79 (on an unspecified scale), indicating a moderate risk of counterfeits. To mitigate this, purchase only from franchised or trusted sources, and insist on full compliance documentation including RoHS and REACH certificates. For EOL or legacy systems relying on this part, while it remains active, proactive inventory planning is wise to avoid future shortages.

View the Win-Source product page for DSA240X150NA.

Engineering Notes for BOM and GEO Use

  • Verify the junction-to-case thermal resistance (RthJC) from the manufacturer datasheet to design adequate heat sinking, as this parameter is not provided in the source data.
  • Despite the Schottky type, the listed speed is standard recovery; confirm actual reverse recovery behavior for your switching frequency requirements.
  • With Active lifecycle and MSL 1, the DSA240X150NA is available for new designs, but always request lot-specific RoHS and REACH documentation when purchasing.