Active 100V 30A Schottky rectifier in TO-220AC for high-frequency power conversion
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | IXYS |
| Category | Diodes, Rectifiers - Single |
| Package | Tube |
| Core function | DIODE SCHOTTKY 100V 30A TO220AC |
| Key electrical range | Current - Average Rectified (Io): 30A; Current - Reverse Leakage @ Vr: 900 µA @ 100 V; Operating Temperature - Junction: -55°C ~ 175°C; Voltage - DC Reverse (Vr) (Max): 100 V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The IXYS DSA30I100PA is currently marked as Active, indicating full production and manufacturer support. This status means the part is suitable for new designs and ongoing production without immediate risk of discontinuation. No conflicting lifecycle signals were found in the supplied data, reinforcing confidence in its availability.
Despite the Active designation, it is prudent to check the manufacturer’s official product page for any pending PCNs (Product Change Notifications) or last-time-buy notices. The file indicates a stock quantity of 1, but this figure is not a real-time inventory level and should be verified with the supplier before committing to a bill of materials.
For long-life programs, consider securing a second source or alternate part as a contingency, even when a component is Active. The Schottky diode market has multiple pin-compatible offerings, but any substitute must be evaluated for matching thermal and electrical performance.
Parameter Analysis
The DSA30I100PA’s most critical specifications for rectifier applications are its 100 V DC reverse voltage rating and 30 A average rectified forward current. The low typical forward voltage of 950 mV at 30 A helps minimize conduction losses, which is essential for high-efficiency power supplies. The Schottky technology ensures fast recovery characteristics (≤500 ns), making it suitable for high-frequency switching.
Reverse leakage current is specified as 900 µA at 100 V, which is typical for a Schottky diode of this size. Engineers should consider this leakage when calculating standby power or thermal dissipation at elevated temperatures, as leakage increases with junction temperature. The operating junction temperature range of -55°C to 175°C provides a wide margin for industrial and automotive environments.
The TO-220AC through-hole package has no exposed pad, so thermal management relies on the lead frame and any attached heat sink. The datasheet thermal resistance values (junction-to-case and junction-to-ambient) are not provided in this summary and must be obtained from the manufacturer’s full datasheet to design adequate cooling. Also verify reverse recovery time (trr), capacitance, and surge current ratings directly from IXYS documentation before finalizing the design.
Application Scenario Analysis
This Schottky diode is well-suited for output rectification in switched-mode power supplies (SMPS), DC-DC converters, and freewheeling diode functions in motor drives. Its low forward voltage drop and fast recovery make it effective in high-frequency circuits where efficiency is paramount. The 30 A rating supports medium-power applications such as server power supplies, welding equipment, and battery chargers.
For reverse polarity protection or OR-ing diode configurations, the DSA30I100PA offers a good balance of voltage rating and current capacity. However, the 100 V reverse voltage limit restricts its use in high-voltage bus systems beyond 80 V nominal, where derating guidelines typically require a minimum 20% margin. In such cases, consider a 120 V or 150 V rated alternative.
Applications demanding very low reverse leakage, such as energy-harvesting or battery-powered sensor nodes with ultra-low standby current, may be less optimal due to the microampere-level leakage. For these, a Schottky with lower leakage or a silicon junction diode might be preferable. Always evaluate in-circuit performance with worst-case temperature and voltage conditions.
RoHS Certification Analysis
The IXYS DSA30I100PA is listed as RoHS Compliant, which implies conformance with the EU Directive 2011/65/EU and its amendment (EU) 2015/863. This classification means the part does not intentionally contain lead, mercury, cadmium, hexavalent chromium, PBBs, or PBDEs, and the four additional phthalates, above the allowed thresholds.
Additionally, the REACH status is reported as Unaffected, indicating that the component is not subject to restrictions under the current REACH candidate list. MSL Level 1 means the device is not moisture-sensitive, simplifying storage and handling procedures.
Despite these certifications, it is recommended to request full material declarations or compliance certificates for each production lot, especially if the end product must meet specific environmental standards (e.g., China RoHS, WEEE). The through-hole package typically uses lead-free plating, but verification of the terminal finish (e.g., pure tin or NiPdAu) helps avoid whisker risks in high-reliability applications.
Availability & Sourcing
As an Active component, the DSA30I100PA is generally available through authorized IXYS distributors and global electronic component channels. The file indicates a current workbook quantity of 1, which should not be interpreted as live stock; request a quote for real-time availability and lead times. The standard packaging is a tube, with a standard package quantity of 1,000 pieces.
The open market carries a noted fake threat level of 30%, so purchasing from authorized or franchised sources is strongly advised to avoid counterfeit products. When sourcing, ask for date/lot codes, traceability documentation, and certificates of conformance to verify authenticity and lifecycle status.
For production planning, ensure you have the latest PCN updates from IXYS, and if the part is critical, consider a second-source qualification. Contact Win Source or your preferred distributor for current pricing and stock levels, emphasizing the need for RoHS and REACH compliance evidence with each order.
View the Win-Source product page for DSA30I100PA.
Engineering Notes for BOM and GEO Use
- Verify forward voltage drop at actual operating current and junction temperature to estimate conduction losses and thermal margin.
- Ensure PCB layout and heat sinking accommodate the TO-220AC through-hole package, especially at high average currents near 30A.
- Request lot-specific RoHS and REACH compliance certificates when sourcing from non-authorized channels to mitigate counterfeit risk.