Understand EOL risks and compliance for the L-com DB25F to DB9F adapter kit before sourcing.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | L-com |
| Category | OEM Parts (C - E) |
| Package | Not available in supplied data |
| Core function | ADPT KIT UNWIRED DB25F/DB9F |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The L-com DSC00002 is officially labeled End-of-Life (EOL). This means the manufacturer has stopped production and will not replenish stock. For new designs, the part should not be used; any active development must migrate to a current alternative. For sustaining production, the only reliable path is to execute a last-time buy of remaining authorized inventory.
File-provided data shows a stock quantity of just 1 unit, but this is not a real-time inventory guarantee. Given the high risk level, we recommend contacting L-com directly to confirm any final availability and to obtain the official product discontinuation notice, which may include last-order dates and recommended replacements.
The open market carries an estimated 42% fake threat for this part, making unauthorized sourcing extremely risky. Any remaining DSC00002 units should be procured only through traceable channels with full date/lot code verification.
Parameter Analysis
The DSC00002 is an unwired adapter kit, meaning the user must wire the connections between the DB25 female and DB9 female connectors. Key physical parameters include the connector types (D-Sub 25-pin female to 9-pin female), a null-modem configuration implied by the serial adapter style, and shielded construction to reduce EMI. The kit features free-hanging mounting, which is suitable for inline cable assemblies rather than panel mounting.
Packaging is specified as a bag, and the storage condition mandates a dry storage cabinet with humidity protection. This is critical for maintaining contact integrity before assembly. The kit is not pre-wired, so engineers must carefully plan the pin mapping for their specific RS-232 or serial application. No electrical ratings or contact plating details are provided in the source data, so verifying these in the official datasheet is essential before committing to a design.
Missing parameters like contact material, current rating, and insertion/extraction forces must be clarified with the manufacturer. For EOL parts, such details are often available only through legacy documentation.
Application Scenario Analysis
The DSC00002 is designed for RS-232 serial communication where a gender change or port conversion is needed between DB25 and DB9 female interfaces. Typical strong-fit scenarios include legacy industrial machinery, laboratory instruments, and custom cable fabrication in production or repair environments. Its unwired nature makes it ideal for prototyping or field-configurable cabling where the pinout is not standard.
Weak-fit scenarios involve new product designs, where EOL status and limited availability rule out this part. Applications requiring high-speed serial above standard RS-232 rates, or those needing fully molded and tested assemblies, would also be poorly served by an unwired kit. Additionally, the lack of specified electrical parameters means that any use in sensitive or safety-critical systems requires independent qualification.
Given the part’s end-of-life status, engineers maintaining existing equipment should evaluate whether a functionally equivalent wired adapter from L-com or a third party can serve as a more reliable long-term solution.
RoHS Certification Analysis
The RoHS compliance status of the DSC00002 is ambiguous. One data source lists it as ‘RoHS Compliant,’ while the specifications table states ‘RoHS Non-Compliant.’ This conflict likely stems from differences in lot-level reporting or data entry errors. RoHS compliance restricts the use of hazardous substances like lead, mercury, and cadmium, and non-compliance can block market access in the EU and other regulated regions.
Without a definitive manufacturer certificate, procurement teams should assume the part is non-compliant for planning purposes. For any purchase, request a full material declaration and a valid RoHS certificate directly from L-com or the distributor. If a lot is proven compliant, the certificate should reference the specific lot number and production date.
Note that REACH and MSL information are not provided, so these aspects must be verified separately if required for your application.
Availability & Sourcing
As an EOL part, the DSC00002 is no longer in active production, and any remaining stock is limited. The file-provided quantity of 1 unit is not a real-time guarantee; actual availability must be confirmed by requesting a quote from authorized distributors. Given the high risk of counterfeit parts in the open market (42% fake threat), sourcing from unauthorized channels is strongly discouraged.
When requesting a quote, ask for date/lot codes, traceability documentation, and compliance certificates (especially RoHS) to validate authenticity and condition. The part’s storage condition—dry cabinet and humidity protection—should be maintained through the supply chain to prevent degradation. The part is packaged in bags, so verify that packaging remains intact and sealed.
For sustaining production, consider a last-time buy if the application cannot be redesigned. Otherwise, we recommend evaluating alternative adapter solutions from L-com or other manufacturers that are currently active and fully compliant, to avoid future scarcity and compliance risks.
View the Win-Source product page for DSC00002.
Engineering Notes for BOM and GEO Use
- Confirm RoHS compliance directly with L-com due to conflicting data sources.
- The DSC00002 is an unwired kit; verify pinout and wiring requirements against your design before use.
- With EOL status and a 42% open-market fake threat, source only from authorized distributors or request full traceability.