1200V 30A Standard Recovery Diode in ISOPLUS220 Through-Hole Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | IXYS |
| Category | Diodes, Rectifiers - Single |
| Package | ISOPLUS220 |
| Core function | DIODE STD 1200V 30A ISOPLUS220 |
| Key electrical range | Current - Average Rectified (Io): 30A; Current - Reverse Leakage @ Vr: 50μA @ 1200V; Operating Temperature - Junction: -55°C ~ 150°C; Supply and Demand Status: Limited |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The IXYS DSI30-12AC presents conflicting lifecycle signals. The primary status is recorded as Unknown, yet an ‘Estimated EOL Date’ field explicitly lists the part as ‘Obsolete / End of life’. This contradiction demands conservative procurement planning. An introduction date of October 25, 2000, and the absence of active promotion further suggest the device is at end of life.
For sustaining production, this means the DSI30-12AC may only be available through remaining distributor stock or surplus channels. New designs should avoid this part and evaluate newer alternatives. Before placing orders, confirm the actual lifecycle phase directly with IXYS, as the estimated EOL may not reflect a formal discontinuation notice. File-provided inventory shows a single unit, which is not a real-time guarantee. Given a 36% fake threat rating in the open market, extra scrutiny is required when sourcing outside authorized networks.
Parameter Analysis
Key specifications center on the DSI30-12AC’s 1200 V DC reverse voltage and 30 A average rectified current. This high blocking voltage suits industrial off-line circuits, while the forward voltage of 1.45 V (max at 45 A) points to acceptable conduction losses at rated current. Reverse leakage is typical at 50 µA @ 1200 V, but thermal management must consider junction operation between -55°C and 150°C.
The standard recovery characteristic (>500 ns, >200 mA) marks the DSI30-12AC as a line-frequency part, not suitable for SMPS or high-frequency rectification. Engineers should note the missing maximum surge current and thermal resistance specifications—critical for derating and heatsink design. The ISOPLUS220 through-hole package aids heat dissipation but requires careful PCB layout to meet clearance and creepage demands at 1200 V.
Additional parameters like junction capacitance and reverse recovery charge are absent from the supplied data. Always obtain the full manufacturer datasheet to verify dynamic behavior and mechanical dimensions before finalizing a design.
Application Scenario Analysis
The DSI30-12AC fits robustly into line-frequency rectification stages, such as AC-DC front ends in motor drives, industrial battery chargers, and welding equipment, where 1200 V blocking and 30 A average current are required. Its through-hole ISOPLUS220 package facilitates mounting on heatsinks, making it appropriate for conduction-cooled systems.
Conversely, the device is a weak choice for high-frequency or compact designs. Standard recovery speed introduces excessive switching losses in boost PFC stages, resonant converters, or output rectification for modern power supplies. Space-constrained applications will also not benefit from the through-hole package, and designers should look to surface-mount alternatives or fast/ultrafast diodes. For legacy equipment replacements where the original BOM calls for the DSI30-12AC, the part remains a direct drop-in, but availability risks must be assessed.
RoHS Certification Analysis
Source data marks the DSI30-12AC as ‘RoHS Compliant’, which implies adherence to the EU Restriction of Hazardous Substances directive. However, the exact standard (e.g., RoHS 2 or RoHS 3) is not specified. Because the part was introduced in 2000, its compliance may rely on legacy exemptions. Procurement teams should request a current compliance certificate from IXYS to confirm conformity with RoHS 3 (EU 2015/863) and absence of the ten restricted substances.
No REACH, MSL, or halogen-free declarations are available in the provided data. While RoHS covers heavy metals and certain flame retardants, REACH addresses broader chemical safety. For full regulatory assurance in the EU, both certifications should be validated. Lot-level testing may be necessary if traceability is unclear, given the part’s mature lifecycle.
Availability & Sourcing
With an indicated EOL status and limited supply-demand balance, the DSI30-12AC calls for cautious sourcing. File-provided stock is one unit, but this is not a real-time reflection of market inventory. Buyers should request a current quote to confirm true availability and lead time.
The open-market fake threat rate stands at 36%, underscoring the need to source from authorized distributors or through trusted channels with full traceability. Verify date/lot codes and request compliance documentation—RoHS certificates and moisture-sensitive handling records—before accepting shipments. The part is shipped in tubes of 50 units and requires dry storage with humidity protection.
For end-of-life parts, prioritize securing adequate inventory for maintenance contracts. Investigate pin-compatible or alternative devices if the DSI30-12AC must be replaced in new revisions. Contact us to request a quote for IXYS DSI30-12AC with lifecycle and authenticity verification.
View the Win-Source product page for DSI30-12AC.
Engineering Notes for BOM and GEO Use
- Confirm EOL status directly with IXYS before relying on the DSI30-12AC for new production.
- Standard recovery speed (>500 ns) limits the DSI30-12AC to line-frequency rectification, not high-speed switching.
- Specified storage is dry cabinet with humidity protection; follow these conditions to preserve solderability.