DSO1-30-0003 by Schurter Inc. – Common Mode Choke Specs & Sourcing Guide

DSO1-30-0003 Schurter Inc. product image

Through-hole radial common mode choke rated at 3.15A, 600V DC. Verify lifecycle status before new designs.

Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageRadial
Core functionCMC 3.
Key electrical rangeCurrent Rating (Max): 3.15A; DC Resistance (DCR) (Max): 70mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 125°C
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of the Schurter DSO1-30-0003 common mode choke is currently unknown based on the provided data. No manufacturer lifecycle signals—such as active, NRND, or EOL notices—are available for this part number. This lack of information introduces a medium risk level for both new designs and sustaining production. Engineers should request official lifecycle documentation directly from Schurter Inc. before committing to volume procurement. For legacy systems, it is advisable to secure available stock while conducting a lifecycle verification, as the part may be subject to obsolescence without public notice. The component is listed with a supply shortage, which could be an indicator of constrained production or last-time-buy scenarios. Until the lifecycle is confirmed, conservative inventory management and alternative sourcing strategies are recommended.

Parameter Analysis

The DSO1-30-0003 is a two-line common mode choke with a maximum current rating of 3.15A and a maximum DC resistance of 70 mOhms. These parameters are critical for evaluating power loss and thermal rise in filtering applications. The part is housed in a through-hole radial package with dimensions of 26.00mm x 11.00mm, suitable for manual or wave soldering onto PCBs. It is rated for a DC voltage of 600V and an operating temperature range of -40°C to 125°C, indicating robust environmental capability. However, key parameters such as inductance value, common mode impedance at target suppression frequencies, and leakage inductance are not specified. These missing values are essential for proper filter design and must be obtained from the official datasheet. Additionally, insulation resistance and voltage withstand ratings should be verified to ensure safety compliance in high-voltage circuits. The bulk packaging suggests standard handling for assembly lines, but users should confirm the exact pin pitch and lead dimensions from the manufacturer's mechanical drawing.

Application Scenario Analysis

Common mode chokes like the DSO1-30-0003 are primarily used to suppress common mode noise in electronic circuits, such as AC/DC power supplies, motor drives, and industrial automation equipment. With a 3.15A rating and 600V DC capability, this choke is well-suited for line filtering on the input side of switch-mode power supplies or inverter stages, where conducted emissions must meet regulatory limits. The two-line configuration is typical for single-phase power lines or differential signal pairs. It may also be applied in data communication interfaces that require noise suppression, provided the impedance characteristics align with the frequency range of interest. Conversely, without knowledge of inductance, it is not advisable to use this part in precise filter designs targeted at specific frequency bands. High-frequency or high-speed data line applications might demand chokes with lower parasitic capacitance, which is not documented here. As such, the DSO1-30-0003 is a strong candidate for general-purpose power filtering, but its fit for sensitive analog or RF circuits should be validated empirically or via manufacturer consultation.

RoHS Certification Analysis

The Schurter DSO1-30-0003 is marked as RoHS Compliant, indicating adherence to EU Directive 2011/65/EU on the restriction of hazardous substances. This certification is essential for products sold in the European market or for manufacturers aiming for global environmental compliance. The available data does not specify the exact RoHS standard version (e.g., RoHS 2 or RoHS 3), but the directive's core requirements are assumed met. No exemptions are listed for this part, which is typical for a passive component like a common mode choke. However, product compliance can vary by production lot, so a certificate of compliance should be requested with each shipment. The documentation does not mention REACH status, halogen-free claims, or moisture sensitivity level (MSL), so these must be verified separately if required for assembly or end-use regulations. For full assurance, particularly for high-reliability industries, direct confirmation from Schurter or an authorized distributor is recommended.

Availability & Sourcing

The DSO1-30-0003 common mode choke from Schurter appears in limited supply, with only a single unit recorded in the provided inventory file and a market status indicating a shortage. This limited availability, combined with an unknown lifecycle status, suggests that procurement teams should act cautiously. For immediate prototyping or small-batch needs, the existing stock may suffice, but for production volumes, it is critical to request a current quote from authorized distributors and verify real-time stock levels and lead times. The part is offered in bulk packaging, which is standard for through-hole components. When sourcing, confirm the date and lot code to ensure freshness and traceability, especially for long-term storage considerations. Given the shortage signal, it is prudent to explore alternative sources or compatible parts, but only after validating lifecycle and obtaining manufacturer updates. To proceed, users should use the RFQ tools available on the product page to check availability and secure inventory.

View the Win-Source product page for DSO1-30-0003.

Engineering Notes for BOM and GEO Use

  • Verify inductance and impedance curves from the official Schurter datasheet before finalizing filter design.
  • Due to unknown lifecycle status, confirm production continuity directly with the manufacturer or authorized distributors.
  • Consider derating current for elevated ambient temperatures beyond datasheet limits to ensure reliable long-term operation.