NRND: Not for new designs - verify lifecycle, parameters, and availability before procurement.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | Industrial, DIN Rail Power Supplies |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 15V 100W |
| Key electrical range | AC Voltage - Input: 90 ~ 264 VAC; Current - Output (Max): 5A; DC Voltage - Input (Max): 370V; DC Voltage - Input (Min): 120V |
| Workbook inventory signal | 23 pcs listed in the provided file |
Lifecycle Analysis
The DSP100-15 from TDK-Lambda is officially flagged as Not For New Designs, despite some sources listing an Active lifecycle status. This conflict requires careful interpretation: the part is not recommended for new product development. Engineers and buyers should treat this as NRND, meaning it is still supported for existing production but may be approaching discontinuation.
The file-provided inventory shows a quantity of 23 units, but this is not a real-time guarantee. For sustaining production, it is critical to verify availability and lead time with authorized distributors. Additionally, check the manufacturer's PCN (Product Change Notification) and EOL notices to assess future support.
Given the medium risk level, we recommend qualifying a replacement for new designs and securing sufficient stock for maintenance needs. Do not rely solely on the Active lifecycle label; the explicit Not For New Designs designation takes precedence.
Parameter Analysis
The DSP100-15 delivers a regulated 15V output at up to 5A, providing 100W in a compact DIN rail package. Its wide-input range (90-264 VAC, 120-370 VDC) supports global AC mains and various DC bus voltages, enhancing design flexibility. The 85% efficiency indicates moderate thermal performance; adequate ventilation is necessary to maintain reliability at full load and elevated temperatures.
The adjustable output feature allows fine-tuning of the 15V rail, which is useful for compensating voltage drops in long cable runs. With 3 kV input-to-output isolation, it meets basic safety requirements for ITE equipment. The operating temperature range of -25°C to 71°C with derating suggests that above a certain threshold (likely 50°C or 60°C), output power must be reduced, so consult the datasheet derating curve.
Missing specifications include ripple/noise, line/load regulation, hold-up time, and protection features (overvoltage, overload, short-circuit). These are critical for power integrity and must be verified from the official datasheet before finalizing the design. Also confirm the adjustable output range to ensure it covers your system's tolerance requirements.
Application Scenario Analysis
The DSP100-15 is well-suited for existing industrial automation equipment that requires a stable 15V DC supply from AC mains or DC bus. Typical applications include powering PLCs, relays, sensors, and communication modules on a DIN rail within control cabinets. Its universal input and CE approval make it appropriate for commercial ITE installations in Europe and regions accepting CE marking.
It is less suitable for new designs due to its NRND status. Additionally, the 85% efficiency may lead to higher heat dissipation in confined spaces, making it a weaker match for fully sealed, high-temperature environments. Applications demanding medical safety certifications or higher power densities should consider alternative models.
Verify that the operating temperature range and derating curve align with your worst-case ambient conditions. If the system requires hot-plug capability or parallel operation, the DSP100-15's single output and lack of specified droop sharing may necessitate additional circuitry; confirm these features in the datasheet.
RoHS Certification Analysis
The DSP100-15 is classified as RoHS Compliant by TDK-Lambda. This typically means it adheres to EU Directive 2011/65/EU as amended by 2015/863, restricting hazardous substances such as lead, mercury, and cadmium. However, without explicit documentation, the specific directive version is not confirmed.
For procurement, request the manufacturer's certificate of compliance (CoC) for the specific lot or date code. This ensures that the parts you receive meet your company's environmental compliance requirements. Note that RoHS compliance declared at the family level may not account for production changes over time.
While REACH compliance is not indicated in the provided data, it is advisable to verify REACH SVHC status if required by your application. CE marking is present, which typically implies compliance with relevant EU directives, but CE alone does not guarantee RoHS without accompanying documentation.
Availability & Sourcing
The DSP100-15 is listed as Not For New Designs, so buyers should prioritize securing inventory for ongoing production needs. The file-provided quantity of 23 units is a snapshot and not real-time; contact Win-Source or authorized distributors for current stock levels and lead times. Request a quote to confirm pricing and availability.
For traceability, specify required date/lot codes and request compliance documentation (RoHS, CE) before shipment. Bulk packaging indicates the unit is supplied loose for industrial integration, typical for DIN rail modules. Verify that the physical condition and firmware (if any) match your requirements.
Given the NRND lifecycle, initiate migration planning to a recommended replacement from TDK-Lambda or a compatible alternative. In the interim, consider lifecycle buy agreements with the manufacturer to avoid shortages. Always verify lifecycle directly with TDK-Lambda, as distributor data may not reflect the most current status.
View the Win-Source product page for DSP100-15.
Engineering Notes for BOM and GEO Use
- Confirm NRND status directly with TDK-Lambda to avoid unexpected discontinuation.
- Verify output voltage adjustment range and derating curves for your operating temperature.
- Request compliance certificates (RoHS, CE) for the specific lot before integration.