24V 100W DIN rail power supply with adjustable output and universal input – NRND status, secure inventory and evaluate migration.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | Industrial, DIN Rail Power Supplies |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 24V 100W |
| Key electrical range | AC Voltage - Input: 90 ~ 264 VAC; Current - Output (Max): 3.8A; DC Voltage - Input (Max): 370V; DC Voltage - Input (Min): 120V |
| Workbook inventory signal | 29 pcs listed in the provided file |
Lifecycle Analysis
TDK-Lambda has assigned a Not For New Designs (NRND) status to the DSP100-24/C2 DIN rail power supply, indicating that the manufacturer does not recommend its use in new product development. While some databases may still list the lifecycle as Active, the safest procurement interpretation is NRND. For existing designs, the part remains available for sustaining production, but engineers should initiate qualification of an alternative to mitigate future obsolescence risk.
The medium risk level reflects the limited remaining product life and the potential for supply interruptions. Verify the current lifecycle status directly with TDK-Lambda before committing to long-term production schedules. This part is suitable only for legacy systems where redesign is not immediately feasible, and inventory should be secured to cover anticipated lifetime demand.
Parameter Analysis
The DSP100-24/C2 provides a single 24V output at up to 3.8A, delivering 100W of power. It accepts a universal AC input range of 90 to 264 VAC, or a DC input from 120 to 370V, making it versatile for global applications. Efficiency is rated at 89%, which impacts thermal design and energy consumption. Isolation voltage is 3 kV, providing basic input-to-output isolation.
The operating temperature range is -25°C to 71°C with derating, so designers must account for load and ambient temperature curves when laying out thermal management. Features include adjustable output voltage and universal input. Critical missing specifications that should be verified from the official datasheet include hold-up time, output ripple and noise, line and load regulation, protection features (overvoltage, overcurrent, short-circuit), and MTBF. The compact dimensions of 55.6mm x 89.9mm x 90.9mm facilitate DIN rail integration in crowded cabinets.
Application Scenario Analysis
The DSP100-24/C2 is intended for ITE (Commercial) applications, typically in industrial control systems, factory automation, building management, and test equipment where DIN rail mounting is standard. Its 24V output suits powering PLCs, sensors, relays, and motor drives. The universal input and adjustable output enhance flexibility.
However, this supply is not suitable for outdoor or harsh environments without additional protection, as its approval is limited to CE and no ingress protection rating is provided. It also lacks medical or safety-critical certifications, limiting use in those fields. For new equipment designs, the NRND status means it should be avoided; instead, consider an active alternative from TDK-Lambda or comparable vendors.
RoHS Certification Analysis
The part is marked RoHS Compliant, indicating compliance with EU hazardous substance restrictions. However, the specific directive version, such as EU 2015/863 (RoHS 3), is not mentioned in the available data. For NRND products, compliance may have been certified under an earlier standard, and newer production requirements could differ.
Engineers should request a certificate of compliance for the specific lot to confirm adherence to current RoHS directives. REACH status is not provided and should be verified separately if required. As with all power supplies, verify that no exemptions apply that could affect product acceptance in certain markets.
Availability & Sourcing
A workbook quantity of 29 units is noted, but this figure is file-provided and not a guarantee of real-time stock. The supply-and-demand status is listed as Shortage, indicating potential procurement challenges. Given the NRND lifecycle, buyers should secure inventory for sustaining needs and evaluate migration paths for new designs. The part is supplied in bulk packaging.
When sourcing, request a quote to confirm current availability, lead time, and lot date codes. Verify authenticity and traceability through authorized distributors to avoid counterfeit risk. For compliance, ensure RoHS and CE documentation is provided with the order. Due to the NRND status, it is critical to confirm with the manufacturer the last-time-buy date and any pending discontinuation notice.
View the Win-Source product page for DSP100-24/C2.
Engineering Notes for BOM and GEO Use
- The DSP100-24/C2 is Not for New Designs; select an active alternative for new projects and initiate migration planning for existing systems.
- Verify derating curves for the -25°C to 71°C operating range to ensure sufficient margin at full load and high ambient temperatures.
- Due to shortage status and NRND lifecycle, authenticate sourcing and confirm real-time availability through authorized channels before committing to production.