Active general-purpose relay with 6VDC latching coil, 8A SPST-NO contacts, through-hole, fully sealed.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Power Relays, Over 2 Amps |
| Package | Bulk |
| Core function | RELAY GEN PURPOSE SPST 8A 6V |
| Key electrical range | Coil Current: 50 mA; Coil Voltage: 6VDC; Contact Rating (Current): 8 A; Must Operate Voltage: 4.8 VDC |
| Workbook inventory signal | 1419 pcs listed in the provided file |
Lifecycle Analysis
The DSP1A-L2-DC6V is classified as Active with a low risk level, based on the supplied lifecycle signals. All available indicators, including the dedicated lifecycle status field and the excel parameter, align without conflict. This status means the relay is fully supported for new designs and can be procured for ongoing production without immediate obsolescence concerns.
Engineers should still perform periodic lifecycle revalidation directly with Panasonic, especially for programs with expected long production runs. While the part is currently active, the supply and demand status notes a shortage condition, suggesting that lead times may be extended. Planning buffers are recommended.
The file-provided inventory shows 1,419 units, but this figure is not a real-time guarantee. Actual warehouse stock may differ, and allocation policies can affect availability. Therefore, always request a current quote to confirm quantities before placing production orders.
Parameter Analysis
The DSP1A-L2-DC6V key ratings include a 6 VDC latching dual coil, an 8 A contact current limit, and maximum switching of 2000 VA (AC) or 1000 W (DC). The latching coil type (50 mA pulse) is critical because it removes the need for continuous coil power, but it requires a bipolar drive. The must-operate voltage is 4.8 VDC, so 6 VDC nominal provides adequate margin; however, the missing must-release voltage should be verified from the datasheet to ensure the coil does not drop out under supply dips.
The 10 ms operate / 5 ms release times suit low-to-mid-speed power switching. The AgSnO contact material offers excellent arc erosion resistance for high inrush loads, but for very low-current signal switching, gold-flash alternatives may be more appropriate. The operating temperature range of -40 °C to 60 °C is typical for power relays; engineers must confirm that the internal coil heating does not push the ambient limit when the relay is enclosed. Key missing parameters include coil insulation breakdown voltage, dielectric strength, and mechanical endurance cycles, which should be checked in the official Panasonic datasheet for compliance with safety standards.
Application Scenario Analysis
The DSP1A-L2-DC6V is well-suited for general-purpose power switching in industrial control panels, HVAC equipment, home appliances, and lighting systems. Its latching characteristic makes it valuable in battery-powered or energy-conscious designs where coil power dissipation is undesirable. The fully sealed construction also supports dusty or mildly corrosive environments.
For high-speed switching (above a few Hz) or precise timing circuits, the 10 ms operate time may be a limitation, and solid-state alternatives could be considered. Similarly, applications requiring low thermal offset or microvolt-level signal contact resistance should avoid power relays and opt for signal relays with gold contacts. High DC switching at 125 VDC with inductive loads requires careful arc suppression, as the 1000 W DC rating may be optimistic without flyback diodes.
Engineers should also verify that the cURus and VDE approvals cover the specific end-equipment safety standards. While the relay itself is approved, integration into a final product may require additional testing.
RoHS Certification Analysis
The supplied data labels the DSP1A-L2-DC6V as RoHS Compliant. Typically, this indicates compliance with EU Directive 2011/65/EU and its amendments, including the substance restrictions of RoHS 3 (EU 2015/863). However, the exact standard version is not explicitly stated in the dataset, so it is prudent to obtain the full Declaration of Conformity from Panasonic.
No RoHS exemptions are noted, though the relay’s construction (AgSnO contacts, sealed plastic housing) usually does not require them. While REACH compliance is not mentioned, it is separate from RoHS and should be checked if required by application. For military or aerospace usage, additional material restrictions may apply.
Procurement teams should request a batch-level RoHS certificate with each shipment, as compliance can vary across production lots, especially for older designs. Even when a part is marked compliant, dated documentation protects against non-conformance findings during final product audits.
Availability & Sourcing
The DSP1A-L2-DC6V is currently in an active lifecycle phase, but the dataset indicates a supply shortage status. File-provided inventory shows 1,419 units; however, this number is not guaranteed in real time. Engineers and buyers should initiate an RFQ (request for quote) process to obtain current stock levels, lead times, and pricing—though pricing is not displayed here.
Sourcing best practices include verifying the manufacturer’s current lifecycle statement, requesting lot/date code traceability, and ensuring compliance documentation (RoHS, REACH if needed) accompanies each delivery. The relay is packaged in bulk, so extra handling may be required for automated placement.
To secure production quantities, engage with authorized distribution early and consider safety stock for this part number. For new designs, confirm that the DSP1A-L2-DC6V remains the recommended active part and that no planned changes (such as a PCN) are pending. Request a quote today for the most up-to-date availability and compliance verification.
View the Win-Source product page for DSP1A-L2-DC6V.
Engineering Notes for BOM and GEO Use
- Latching dual-coil design eliminates continuous coil power dissipation but requires bipolar drive circuitry; ensure your control circuit provides the necessary pulse polarity.
- Contact rating of 8 A at 250 VAC / 125 VDC must be derated for inductive loads according to the manufacturer’s datavsheet; verify maximum switching curves for your load type.
- Fully sealed package may allow board washing, but confirm seal integrity and MSL rating before production processing; through-hole PC pins suit automated insertion.