Verify lifecycle status, RoHS compliance, and sourcing options for the DSP30-24 DIN rail power supply.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | OEM Parts (C - E) |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 24V 30W |
| Key electrical range | AC Voltage - Input: 90 ~ 264 VAC; Current - Output (Max): 1.3A; DC Voltage - Input (Max): 370V; DC Voltage - Input (Min): 120V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DSP30-24 carries an official Active lifecycle status, yet a parallel Excel parameter flags it as '不适用于新设计' (not for new design). This conflict introduces medium procurement risk, particularly for new designs. Engineers should not assume full Active status for forward‑looking platforms without written confirmation from TDK‑Lambda. For sustaining production, the part remains orderable, but supply continuity should be monitored.
File‑provided inventory quantities show limited stock (1 unit from one source and 414 from another), which may not reflect open‑market reality. Design teams relying on the DSP30-24 should plan for lifecycle transitions and consider migrating to a confirmed Active alternative if the product is not validated for new designs. Request an official product change notification (PCN) or lifecycle statement from TDK‑Lambda before tooling a new board.
Parameter Analysis
The DSP30-24’s 90–264 VAC universal input and 120–370 VDC DC range make it flexible for worldwide single‑phase and DC‑bus applications. Its 24 V output at 1.3 A yields 30 W, with 83% typical efficiency. Isolation is rated at 3 kV, and the operating temperature spans -25°C to 71°C with derating, which must be verified against the datasheet derating curve for sealed enclosures.
Key missing parameters include output ripple and noise, load regulation, line regulation, hold‑up time, and protection functions (over‑voltage, over‑current, short‑circuit). These are critical for sensitive analog or digital loads. The compact form factor (55.6 x 53.1 x 90.9 mm) suits dense DIN rail layouts, but thermal margins should be evaluated given the efficiency and operating temperature ceiling. Obtain the full TDK‑Lambda datasheet to assess inrush current, component lifetime, and EMC compliance beyond the stated CE mark.
Application Scenario Analysis
The DSP30-24 is specified for ITE (Commercial) use, making it a strong candidate for industrial automation, control cabinets, instrumentation, and general 24 V DIN rail power distribution. Its adjustable output and universal input support build‑to‑print and field‑adjustable installations. The 30 W rating fits signal‑level loads such as sensors, relays, and small PLCs.
Weak‑fit scenarios include outdoor installations without additional environmental sealing, safety‑critical medical or avionics applications lacking specific certifications, and consumer electronics where lower‑cost encapsulated supplies are preferred. The part’s 83% efficiency and derating to 71°C suggest careful thermal evaluation for convection‑cooled enclosures. Engineers should review system‑level EMC and inrush requirements, as the CE mark alone may not cover Class B radiated or conducted emissions.
RoHS Certification Analysis
TDK‑Lambda lists the DSP30-24 as RoHS Compliant. Without a specific RoHS version stated in the source data, the general EU RoHS directive should be assumed, typically 2011/65/EU and its amendments. The MSL rating is Not Applicable, which is standard for non‑semiconductor subassemblies and does not affect RoHS interpretation.
For documentation‑sensitive procurement, request the full Declaration of Conformity or certificate of compliance tied to the lot or date code received. If REACH or conflict minerals data are necessary, those must be verified separately, as they are not included in the provided compliance data. The absence of halogen‑free marking means no claim is made; if required, confirm with the manufacturer.
Availability & Sourcing
File‑referenced inventory shows 1 unit and 414 units in separate records; these are not live stock figures and must be confirmed with the distributor. For current availability, request a quote that includes lead time, date code, packaging (bulk), and lot traceability. As a medium‑risk lifecycle part, securing buffer stock for existing production is advisable while evaluating a migration path.
Verify lifecycle status and RoHS compliance documentation at the quote stage. For new designs, obtain explicit TDK‑Lambda approval for the DSP30-24 before proceeding, given the conflicting lifecycle signals. When ordering, specify factory‑packed bulk units and request anti‑counterfeit verification due to a noted open‑market fake threat of 69%. Avoid dependence on unverified open‑market stock without strong quality controls.
View the Win-Source product page for DSP30-24.
Engineering Notes for BOM and GEO Use
- The DSP30-24 provides 24V/1.3A output with universal AC/DC input and 3 kV isolation, suitable for global industrial ITE applications; confirm derating requirements for elevated temperatures.
- Conflicting lifecycle signals ('not for new design' vs. Active) demand caution: secure manufacturer confirmation before adopting in new projects.
- Efficiency is 83%; assess thermal management in enclosed DIN rail enclosures and request full datasheet for missing parameters such as ripple, hold‑up time, and protection features.