Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | Industrial, DIN Rail Power Supplies |
| Package | Bulk |
| Core function | AC/DC DIN RAIL SUPPLY 5V 15W |
| Key electrical range | AC Voltage - Input: 90 ~ 264 VAC; Current - Output (Max): 3A; DC Voltage - Input (Max): 370V; DC Voltage - Input (Min): 120V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DSP30-5 from TDK-Lambda Americas Inc. exhibits conflicting lifecycle signals that require careful interpretation. The manufacturer’s Product Status and Lifecycle Status are listed as Active, but an Excel lifecycle parameter explicitly states “不适用于新设计” (not applicable for new design). This inconsistency is a significant red flag for engineers and buyers evaluating the DSP30-5 for new production. A conservative approach must be taken: do not design this part into new applications without direct confirmation from TDK-Lambda.
File-provided inventory shows a limited quantity, which is not a real-time representation of market availability. The risk level is medium, and the recommendation is to verify lifecycle with the manufacturer before any commitment. For sustaining production, this part may remain procurable, but its future roadmap should be clarified with TDK-Lambda to avoid unexpected obsolescence.
Parameter Analysis
The DSP30-5 is a 15W AC/DC DIN rail power supply with key parameters that determine its integration suitability. Input voltage range is universal: 90 to 264 VAC, and also accepts 120 to 370 VDC, making it flexible for global industrial environments. The output is fixed at 5 V with a maximum current of 3 A, delivering 15 W. Efficiency is rated at 74%, which should be factored into thermal management, especially when operating at elevated temperatures. The operating temperature range is -25°C to 71°C, but derating applies; the datasheet derating curve must be consulted for precise limits above +50°C.
Other critical specs include 3 kV isolation, adjustable output voltage (likely a trim range), and CE approval. Missing from the provided data are output ripple and noise, line/load regulation, hold-up time, and protection features such as overload or short-circuit behavior. Engineers should verify these in the official datasheet before finalizing a design, as they directly impact system stability and safety.
Application Scenario Analysis
The DSP30-5 fits well in industrial control cabinets, building automation, and small-scale ITE (commercial) systems where a regulated 5 V rail is needed. Typical strong-fit applications include powering sensors, relays, microcontrollers, and low-power embedded modules on a DIN rail. The adjustable output and universal AC/DC input enhance versatility across different global mains voltages and DC bus systems. Its compact footprint (55.6 × 53.1 × 90.9 mm) and 15 W rating suit it for space-constrained panels.
Weak-fit scenarios include high-power loads exceeding 10-12 W sustained (allowing for derating), outdoor or harsh environments without additional enclosures, and applications requiring very high efficiency or extremely low standby power. The CE marking indicates compliance with European EMC and safety directives, but lack of UL or other national safety certifications may limit use in certain markets unless additional approvals are obtained. Always verify the exact certification status for the target installation.
RoHS Certification Analysis
The DSP30-5 is documented as RoHS Compliant according to TDK-Lambda Americas Inc. data. While the specific RoHS directive version (e.g., RoHS 3 (EU 2015/863)) is not explicitly stated, it typically aligns with current EU requirements. REACH status is unaffected, meaning no substances of very high concern above threshold. The MSL level is not applicable, which is common for open-frame power supplies.
Purchasing teams should request a Certificate of Compliance (CoC) that confirms RoHS compliance at the production lot level, as generic family-level compliance may not account for material changes over time. The presence of a California Prop 65 warning in the data indicates potential exposure to chemicals known to the state, so additional documentation for specific markets may be prudent. No RoHS exemptions are listed, suggesting full compliance without lead or other restricted substance exemptions.
Availability & Sourcing
For the TDK-Lambda DSP30-5 DIN rail power supply, the availability landscape is nuanced. The part carries an Active status but with a conflicting “not for new design” signal from one data source. File-provided inventory indicates limited stock, but this is not a real-time guarantee. Buyers should request a quote to confirm current availability and lead times directly from TDK-Lambda or authorized distribution.
The part is shipped in bulk packaging, with a standard package quantity of one piece. Given the lifecycle ambiguity, engineers sourcing the DSP30-5 for new production should first validate the product’s roadmap with the manufacturer. For sustaining production, secure inventory while verifying lot-level traceability, date codes, and RoHS/REACH compliance documents. Ask for a current lifecycle statement and any PCN (product change notification) history to ensure supply continuity.
View the Win-Source product page for DSP30-5.
Engineering Notes for BOM and GEO Use
- Verify lifecycle with TDK-Lambda before using DSP30-5 in new designs due to conflicting status signals.
- Check derating requirements above 50°C ambient, as the -25°C to 71°C operating range includes derating.
- Request lot-specific RoHS and REACH documentation to ensure compliance for your order.