Omron DST1-MRD08SL-1 sustaining-only PLC I/O module

DST1-MRD08SL-1 Omron product image

4 digital inputs, 8 outputs split 4 relay and 4 solid-state, DIN rail, screw terminals, lifecycle conflict

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryControllers - PLC Modules
PackageBulk
Core functionI/O MODULE 4 DIGITAL 4 RELAY 4SS
Key electrical rangeNumber of Inputs and Type: 4 - Digital; Number of Outputs and Type: 8 - Relay (4), Solid State (4)
Reported stock0 pcs reported — confirm on RFQ

Use it to sustain, not to start

Sustaining only.

The problem is not the I/O mix. It is the lifecycle story. DST1-MRD08SL-1 looks usable at first glance for a small PLC expansion point, but two fields say Active while another points to last sale, and that conflict is enough to keep it out of a fresh platform unless Omron clears it up.

That matters because this is the kind of module a cabinet gets built around. Once the DIN rail position, screw-terminal wiring, and channel assignments are set, a later swap is no longer a simple sourcing change. It becomes a panel rework and service issue.

The functional outline is still clear: 4 digital inputs and 8 outputs, split between 4 relay and 4 solid-state. For an existing machine that already needs that exact mix, the fit can be straightforward. For a new program, the missing electrical ceilings and the lifecycle conflict land harder than the feature list. EU RoHS is straightforward. The lifecycle is not.

4 digital inputs and 8 outputs define the fit

8 outputs.

That is the figure that frames the module, especially because they are not all the same type. The split between 4 relay and 4 solid-state outputs means channel planning has to happen early, not after the panel is wired.

The 4 digital inputs and DIN rail form factor place DST1-MRD08SL-1 in compact cabinet control points where the I/O count is already known and unlikely to move much. Screw terminals reinforce that same use case: serviceable industrial panels, not dense embedded hardware.

What is missing is just as important. There is no supply-voltage field, no per-output current or load rating, no switching-voltage limit, and no isolation figure. Those are the ceilings that decide whether the module fits the job or only looks close on paper.

Wrong for unknown loads, right for fixed cabinet I/O

Wrong for loads that are still undefined.

Right for an existing cabinet build that already knows why it needs 4 relay outputs, 4 solid-state outputs, and 4 digital inputs in one module.

The mounting and termination style make the intended setting plain. This is a PLC module for DIN rail installation with screw terminals, so it belongs in industrial panels where field wiring access matters. It does not fit board-level packaging, high-density connector schemes, or any design that needs a complete electrical picture from the listing alone. Without the supply-voltage and output-limit data, you cannot tell which side reaches its ceiling first.

Zero stock is the immediate constraint

Zero stock is the weak point.

Active labels do not help much if material is unavailable when a sustaining build has to ship. Secure supply before releasing any order tied to DST1-MRD08SL-1.

The missing numbers are the real stop sign

What do you need first to move ahead? The electrical ceilings.

DST1-MRD08SL-1 is missing the supply-voltage field, output current or load ratings, switching-voltage limits, and isolation data. Pinout and mechanical drawing are also absent here, and those details drive cabinet layout and terminal mapping as much as the I/O count does.

So this page can place the module in the right general class, but it cannot tell you whether it will survive the exact loads and wiring scheme you plan to put on it.

View the Win-Source product page for DST1-MRD08SL-1.

Key Takeaways for Engineers & Buyers

  • Hold new releases on DST1-MRD08SL-1 until Omron resolves the last-sale versus Active conflict.
  • Match the panel layout to DIN rail mounting and screw-terminal field wiring before freezing the enclosure.
  • Plan around zero stock now; this is not the module to leave unbuffered on an existing line.