Omron DST1-XD0808SL-1 sustaining-only PLC I/O module

DST1-XD0808SL-1 Omron product image

8 digital inputs, 12 solid-state outputs, DIN rail, screw terminals; lifecycle and RoHS fields need clearing

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryControllers - PLC Modules
PackageBulk
Core functionI/O MODULE 8 DIG 12 SOLID STATE
Key electrical rangeNumber of Inputs and Type: 8 - Digital; Number of Outputs and Type: 12 - Solid State
Reported stock0 pcs reported — confirm on RFQ

The safe call is sustaining only

And that leaves a simple call: keep DST1-XD0808SL-1 on existing production, not a new platform. Active status conflicts with the separate 最后售卖 signal, zero stock tightens the risk, and the RoHS contradiction keeps compliance from being settled.

8 inputs and 12 outputs define the job, not the rail

8 digital inputs and 12 solid-state outputs set the job first: a small mixed I/O node where output count exceeds input count. That matters early, because a control scheme that needs more than 8 digital returns or a different output technology is already on the wrong path before panel layout even starts.

DIN rail mounting and screw-terminal termination narrow the physical fit just as much. This is cabinet hardware with serviceable field wiring, not dense board-level electronics or a harnessed assembly built around another mounting style. The listing also omits any supply-voltage field, so controller-bus compatibility, field-power compatibility, and output-side load matching remain open.

Wrong for voltage-sensitive selection, right for cabinet I/O

Wrong first: any build with tight supply-voltage limits, output switching requirements, or field-side electrical margins should not select DST1-XD0808SL-1 from this page. The missing supply-voltage entry is a hard stop, because it blocks the basic fit check between the module, the PLC system, and the loads it has to drive.

The better fit is plain enough. A cabinet that already expects a DIN rail PLC module with screw terminals and needs 8 digital inputs with 12 solid-state outputs can use this form factor and channel mix well. That points to cabinet I/O expansion, not board-mounted control, and to maintainable field wiring rather than compact sealed assemblies.

Buy constraint: zero stock and unresolved status

Do not buy blind.

Zero stock is the immediate constraint, and it matters more here because the lifecycle picture is split between Active and 最后售卖. For a running line, reserve it only after confirming factory status and actual availability. For a new platform, move on unless this exact I/O mix is already locked by the rest of the system. EU RoHS is not cleanly settled either, because one field says compliant and another says non-compliant.

The missing electrical data is what still blocks release

The constraint is missing electrical limits. Channel count is clear, but the numbers that would support a real release decision are not here. DST1-XD0808SL-1 is identified as an input/output PLC module with 8 digital inputs, 12 solid-state outputs, DIN rail mounting, and screw terminals, yet the listing stops short of the values that decide whether those outputs can live on your loads and whether the module can live on your control power.

The first gap is supply voltage, explicitly absent. Without it, backplane fit and field-power fit stay open. The second gap is output electrical detail: no output voltage range, no output current limit, and no leakage or switching-time data, so the solid-state outputs remain a category label rather than a usable drive specification. The third gap is input threshold behavior; "8 - Digital" gives count, not what the module recognizes as a valid field signal.

Mechanical closure is incomplete too. Beyond DIN rail and screw terminal, there is no drawing, no dimensions, and no terminal map, so panel spacing and wiring access still depend on the datasheet.

View the Win-Source product page for DST1-XD0808SL-1.

Key Takeaways for Engineers & Buyers

  • Hold new BOM release on DST1-XD0808SL-1 until the 最后售卖 signal is resolved.
  • Match the panel build to DIN rail and screw-terminal wiring before freezing layout.
  • Plan around zero stock on DST1-XD0808SL-1 if the line needs immediate coverage.