Pulse DST2-20B44 active, but only for small mains iron

DST2-20B44 Pulse product image

1.1VA max, 115V/230V primary, 10V or 20V secondary, 2500Vrms isolation, through-hole laminated core

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 1.
Key electrical rangeCurrent - Output (Max): Parallel 110mA, Series 55mA; Power - Max: 1.1VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock0 pcs reported — confirm on RFQ

Not for rail-hungry loads

Wrong part for anything that wants real output power. DST2-20B44 is capped at 1.1VA max, with dual secondaries that give either 10V at 110mA in parallel or 20V at 55mA in series, so it fits small mains-derived housekeeping supplies, not boards with much downstream current demand.

The 1.1VA ceiling is the whole design argument

The constraint is simple: 1.1VA max. That number kills any casual overbuild assumption, because the secondary options stay inside a very small power budget: parallel 10V with 110mA max, or series 20V with 55mA max. Those are ceilings, not operating targets, and they decide whether your load can live with a small laminated transformer at all.

Then there is the isolation rating. At 2500Vrms, it supports the basic case for a mains-frequency transformer where galvanic separation is the point, but it does not answer creepage, clearance, hipot duration, or construction details. The dual 115V, 230V primary adds input-wiring flexibility, yet without the winding connection diagram it still does not close a universal-input design, and getting that wrong fails fast.

Form factor matters as much as the schematic here. This is through-hole, PC pin, laminated core hardware at 28.70mm x 28.70mm and 23.86mm seated height, which is easy to justify on industrial or serviceable boards and much harder to defend on dense low-profile assemblies, where transformer volume rather than circuit intent pushes the design out of bounds.

Stock is the weak point; lifecycle is not

Zero on hand is the problem. The lifecycle picture is clean: Active status appears consistently, and EU RoHS is straightforward, so DST2-20B44 is not a sustaining-only part on paper.

The buy-side constraint is simpler than the electrical one: stock quantity is 0 and package is Bulk. If this transformer is already qualified in an existing build, secure supply before another lot is released. If it is for a new program, don't let DST2-20B44 become a schedule assumption until availability is real.

23.86mm height is known; the rest of the fit is still missing

23.86mm seated height is enough to start the conversation. With 28.70mm length and width, through-hole mounting, and PC pins, DST2-20B44 fits older-style mains sections, serviceable control boards, and low-count power islands that can spare board area and vertical space. No center tap narrows the intended use toward straightforward dual-secondary arrangements rather than center-tapped rectifier schemes.

What is still missing is what closes placement and thermal confidence: pinout, mechanical drawing, regulation behavior, and temperature rise data. For a mains transformer, those gaps are not cosmetic. They determine hole pattern, enclosure clearance, and whether the secondary voltage stays where the rest of the circuit expects it under load.

View the Win-Source product page for DST2-20B44.

Key Takeaways for Engineers & Buyers

  • Hold DST2-20B44 to 1.1VA max; that ceiling decides whether the load belongs here at all.
  • Choose the secondary connection up front: parallel gives 10V and 110mA, series gives 20V and 55mA.
  • Stop layout until the pinout and mechanical drawing for DST2-20B44 are in hand.