2500Vrms isolation, 1.1VA max, 115V/230V primary, 12V or 24V secondary, through-hole laminated core
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 1. |
| Key electrical range | Current - Output (Max): Parallel 90mA, Series 45mA; Power - Max: 1.1VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Not for compact or high-load rails
This is the wrong transformer for dense, low-profile boards or anything that needs much output current. The body is 28.70mm L x 28.70mm W, height reaches 23.86mm max, and the output ceiling is only parallel 90mA or series 45mA.
It fits better in a small through-hole mains transformer stage where isolation and simple board mounting matter more than size. The dual 115V, 230V primary and dual secondary add wiring flexibility, but 1.1VA max is still the hard ceiling. That shuts the door on heavier auxiliary rails, and it still leaves regulation, temperature rise, and transient behavior unanswered.
2500Vrms isolation is the deciding number
2500Vrms is the number that puts this part in an offline supply discussion at all. It sets the stated isolation limit between primary and secondary, but it does not answer creepage on your board, agency approvals, or behavior under surge.
The other ratings work as a set. A 12V secondary in parallel with 90mA max and a 24V secondary in series with 45mA max are configuration ceilings, not operating promises. Get that wrong and the rail budget collapses fast. Add the 1.1VA maximum and the message is plain: this is for light auxiliary power, not a rail that keeps growing as features get added.
The package is old-school on purpose
The weak point comes first: through-hole laminated transformers do not win height or assembly-density fights. The upside is just as clear. DST2-24B45 is the kind of part you choose when you want a board-mounted mains transformer with PC pins and no center tap, and you want the implementation to stay straightforward.
Dual primary windings at 115V, 230V let one BOM cover different mains arrangements, while dual secondaries let you choose parallel 12V or series 24V without changing the transformer. That makes it a sensible fit in low-power control boards, interface boards, and serviceable industrial assemblies. It does not belong in slim enclosures, and transformer mass at 0.17 lb can already be a board-mechanics penalty.
Can you actually build with DST2-24B45 now?
Can you get it now? No, not from listed stock. Quantity is 0, and that matters more than the Active lifecycle when a line needs parts.
For a new design, the lifecycle picture is clean enough to keep evaluation moving because both lifecycle fields say Active and there is no conflict. For an existing build, immediate availability is the real constraint, so the supply check comes first and the lifecycle label comes second.
That split matters in practice. If the goal is qualification work, DST2-24B45 still has a workable case: Active status, no lifecycle conflict, and a clear enough electrical outline to judge whether a small mains transformer is even the right architecture. If the goal is near-term production, none of that offsets listed stock at 0.
Packaging is Bulk, which works for bench builds and lower-volume handling, but it gives you no help on automated feed assumptions. RoHS is listed as compliant under EU RoHS, so there is no compliance conflict to solve. The immediate action is simpler: secure availability before releasing anything that depends on DST2-24B45.
What the listing still doesn’t answer
The constraint is missing detail. Pinout, mechanical drawing, regulation, temperature-rise or thermal limits, and winding resistance or equivalent loss detail are still absent, so load-drop judgment stays incomplete.
View the Win-Source product page for DST2-24B45.
Key Takeaways for Engineers & Buyers
- Match the secondary exactly: parallel 12V or series 24V changes the current ceiling to 90mA or 45mA.
- Reserve 28.70mm x 28.70mm board area and 23.86mm height before laying out DST2-24B45.
- Clear supply first; listed stock is 0 even though DST2-24B45 is Active.