Pulse DST2-36B47 active, but not ready off the shelf

DST2-36B47 Pulse product image

1.1VA, 115V/230V primary, 18V parallel or 36V series secondary, 2500Vrms isolation, through-hole laminated core

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 1.
Key electrical rangeCurrent - Output (Max): Parallel 60mA, Series 30mA; Power - Max: 1.1VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock0 pcs reported — confirm on RFQ

The electrical limits fit small mains rails, not much beyond

And that is the real call on DST2-36B47: a small mains transformer for modest board power, provided the load stays inside its listed ceilings and you can live with a thin public spec.

The 1.1VA rating is the first hard boundary, and it keeps this part in low-power housekeeping rails, simple linear supplies, and isolated support functions rather than anything with much load behind it. The secondary options reinforce that limit: 18V in parallel with 60mA max, or 36V in series with 30mA max. Those are ceilings, not normal operating targets, so any design that needs startup headroom or room for sustained load growth is already pushing the wrong transformer.

The 2500Vrms isolation rating matters because it establishes the transformer interface as a mains-side isolation barrier, but it still leaves board-level questions open. Creepage, clearance, and construction detail are not covered here, and neither are thermal rise, copper loss split, or ambient headroom. In a sealed product, that missing thermal picture matters more than another repetition of the VA number.

Lifecycle is the easy part. Active status is clean, and EU RoHS compliance is straightforward. Availability is not.

2500Vrms is the number that earns it a place

2500Vrms is the decisive figure here because it makes this a mains-isolation component, not just another low-voltage magnetic.

From there, the fit is practical. Dual primaries support 115V or 230V input, and dual secondaries let you choose 18V parallel or 36V series output. No center tap is listed, so any circuit that expects one is out. Through-hole PC pins and a laminated core point to a conventional board-mounted power section rather than a dense low-profile assembly.

The mechanical envelope is not trivial either: 28.70mm by 28.70mm with 23.86mm seated height. Small transformer. Tall enough to matter.

Can you actually buy DST2-36B47 for a build?

Can you get it in quantity right now? Not from this line item.

Listed stock is 0, and that overrides the otherwise clean Active status. Bulk packaging is normal for a through-hole transformer like this, so the issue is not handling format. It is supply. For an existing production build, secure coverage before the next release. For a new program, don't freeze the schematic around DST2-36B47 until supply is real.

The missing transformer details are the real review gap

The constraint is missing detail.

Pinout, mechanical drawing, and regulation under load are still absent, so PCB land pattern, wiring orientation, and output sag remain open questions.

View the Win-Source product page for DST2-36B47.

Key Takeaways for Engineers & Buyers

  • Lock the secondary scheme early: 18V parallel at 60mA or 36V series at 30mA.
  • Check board height against the 23.86mm seated maximum before committing the enclosure.
  • Plan a buy around 0 stock; don't release DST2-36B47 to build without supply coverage.