Pulse DST2-56B49 discontinued, sustaining use only

DST2-56B49 Pulse product image

1.1VA transformer with 115V/230V primary and 28V parallel or 56V series secondary

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 1.
Key electrical rangeCurrent - Output (Max): Parallel 40mA, Series 20mA; Power - Max: 1.1VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock0 pcs reported — confirm on RFQ

1.1VA is the real limit here

1.1VA sets the boundary. This is a small laminated power transformer, and that ceiling rules out anything beyond light auxiliary rails, bias supplies, or low-current housekeeping power long before the dual-primary flexibility becomes the main attraction.

The rest of the ratings point the same way. The secondary is listed as 28V in parallel or 56V in series, with output current capped at 40mA in parallel or 20mA in series. Those are ceilings, not operating points, so the part belongs in low-load mains-derived sections where modest demand matters more than squeezing every millimeter of board area. Push past that and the likely trouble is straightforward: voltage regulation and temperature rise become the issue, and neither is described here.

The bad news is lifecycle, not isolation

The weak point comes first: DST2-56B49 is discontinued, and listed stock is 0. The strong number is 2500Vrms isolation, but it doesn't put this part back into contention for new design-in.

Dual windings make it flexible, not universal

Sustaining only.

This part still fits existing production when you need exactly this mix of dual 115V, 230V primary options and dual secondary wiring. One transformer can cover different mains inputs and either 28V parallel or 56V series output without changing the basic mechanical envelope.

Its lane is still narrow. Through-hole mounting, PC pins, a laminated core, and a 28.70mm by 28.70mm body with 23.86mm seated height place it on conventional offline boards, not dense low-profile assemblies. No center tap is listed, so any design expecting a tapped secondary for rectifier topology or split rails should stop here. The 0.17 lb mass reinforces the point: this is a real mains magnetics part, not something you slip into a height-constrained daughtercard.

What would actually close the open questions?

What is missing before you trust it in a sustaining build?

Start with regulation under load. Only full-load secondary voltage is shown, while no-load behavior is absent, and that matters on lightly loaded rails where transformer output can drift high.

Thermal detail is missing too: no temperature rise, no thermal class, and no derating curve. Mechanical certainty is also incomplete because there is no pinout or drawing here, even though dual primary and dual secondary windings make phasing and footprint mistakes easy. Protection behavior is another gap; no inrush or fuse guidance is stated, and no short-circuit tolerance is listed. For DST2-56B49, those omissions matter more than another line of copy.

View the Win-Source product page for DST2-56B49.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases on DST2-56B49; lifecycle is Discontinued.
  • Check the secondary wiring early: 28V parallel or 56V series changes the downstream rail plan.
  • Reserve board area for 28.70mm x 28.70mm and 23.86mm height before layout starts.