2500Vrms isolation, 115V/230V primary, 60V or 120V secondary, 2.4VA through-hole transformer
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 2. |
| Key electrical range | Current - Output (Max): Parallel 40mA, Series 20mA; Power - Max: 2.4VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
2.4VA is the real limit, not the 120V secondary
2.4VA is the number that decides whether this transformer belongs in the design. The listing also gives Parallel 60V and Series 120V on the secondary, plus Parallel 40mA and Series 20mA output current, and those figures point to a small-power transformer with little room for extra load, startup overhead, or downstream losses.
The voltage headline can distract from that. A 120V secondary looks generous until the 20mA series current ceiling pulls the part back into signal-level or very light auxiliary-rail work, while the 60V parallel option at 40mA leads to the same conclusion from the other side. Ask it for more apparent power than 2.4VA allows and the mismatch is straightforward.
That keeps Pulse DST3-120B37 in scope for bias supplies, isolated sensing rails, or low-current housekeeping power. It does not fit loads where current is expected to swing around.
The weak point is availability; the strong point is flexibility
Stock is 0. That's the immediate problem, even with an Active lifecycle and no conflicting status signals.
Once supply is covered, the wiring options are useful. The primary is dual and listed for 115V, 230V, while the secondary is also dual with Parallel 60V and Series 120V options. One transformer can therefore serve products built for different line inputs or alternate secondary arrangements without changing the magnetic part.
There are still packaging limits. Bulk packaging, Through Hole mounting, and PC Pin termination place it firmly in the board-mounted laminated-transformer category, not in dense low-profile assemblies or automated reel-fed insertion plans. If this part is already on a running line, secure supply first; for a new build, don't release around zero stock unless the schedule can absorb it.
View the Win-Source product page for DST3-120B37.
2500Vrms isolation helps, but it doesn't finish the safety picture
2500Vrms is the decisive insulation figure here. It keeps the part in scope for offline auxiliary power where primary-to-secondary isolation is the first gate.
It does not answer creepage, clearance, or agency questions, because none of those details appear here. The mechanical envelope matters too: 35.05mm L x 28.70mm W and 30.23mm seated height, with a weight of 0.25 lb (113.4 g). That footprint and mass fit better on boards already laid out for a laminated core transformer than on compact control cards where height and board loading are tight. No center tap is listed, so any design that depends on a center-tapped secondary is out immediately.
The missing details are the ones that close the review
Still incomplete.
A pinout or drawing is still needed, because dual-primary and dual-secondary parts only work when the winding connections are unambiguous on the PCB. Regulation data is also missing, or at least no-load versus full-load voltage behavior; the listing gives only full-load secondary voltage, leaving downstream rectifier and capacitor sizing unresolved.
Thermal rise information and any insulation or safety approvals tied to the 2500Vrms figure are also absent. Without those details, Pulse DST3-120B37 fits the right class of design, but the board release is not closed.
View the Win-Source product page for DST3-120B37.
Key Takeaways for Engineers & Buyers
- Match the primary wiring to 115V or 230V before releasing the schematic.
- Budget the secondary around 2.4VA, not just 60V or 120V.
- Place a stock check now; listed quantity is 0.