2500Vrms isolation, 6VA, dual 115V/230V primary, dual 6.3V or 12.6V secondary
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 6VA TH |
| Key electrical range | Current - Output (Max): Parallel 1A, Series 500mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
6VA is the number that decides this transformer
6VA is the hard ceiling, and it tells you more than the winding labels do. In a small mains-frequency supply where a laminated through-hole transformer is still acceptable, that limit settles the fit fast and rules out any design hoping the dual secondaries somehow turn it into a larger power part.
The listed outputs are paired limits, not operating promises: 6.3V in parallel at 1A, or 12.6V in series at 500mA. Those numbers are enough to screen low-power rails, but they do not answer regulation under load, temperature rise, or how much secondary sag appears at full load. The 2500Vrms isolation rating is a ceiling on insulation stress, not a statement about safety approvals or end-equipment qualification.
33.27mm height can block the mechanical fit first
33.27mm can stop the layout before the schematic is even settled. With a 41.40mm L x 33.27mm W body, through-hole mounting, PC pins, and a 0.44 lb (199.58 g) weight, this is a board-mounted mains transformer that needs real board area and real vertical clearance.
It fits enclosed industrial or bench equipment that already expects a laminated core on the PCB. Thin housings are out. No center tap is listed, so any design that needs a center-tapped secondary is out too.
Can you still buy it?
Can you still buy it? No.
Stock is 0, and DST4-12B6 is discontinued. That ends new design-in; for existing production, treat any remaining market availability as a bridge while you move the BOM.
The real problem is what the listing does not tell you
The constraint is closure: there is enough here to reject DST4-12B6 for new work and enough to place it in an older low-power mains supply, but not enough to release the electrical or mechanical design with confidence.
The missing items are concrete and they change decisions. There is no pinout, so the PCB cannot be locked without the winding arrangement and lead map. There is no drawing beyond overall size, so the hole pattern and keepout still need the datasheet. There is no regulation figure, the number that shows how far the secondary moves from light load to full load.
There is also no temperature-rise, thermal class, or derating information, and that gap keeps the 6VA rating from answering ambient headroom in a closed box. DST4-12B6 gives you the headline limits, then stops short of the details that make a transformer straightforward to release.
View the Win-Source product page for DST4-12B6.
Key Takeaways for Engineers & Buyers
- Treat 6VA as the output ceiling; check your load against the listed 1A parallel or 500mA series limit.
- Confirm the board can take 41.40mm x 33.27mm footprint and 33.27mm seated height before touching layout.
- For existing builds, lock supply now; stock is 0 and DST4-12B6 is discontinued.