Pulse DST4-16B10 discontinued, sustaining use only

DST4-16B10 Pulse product image

6VA, 115V/230V primary, 8V or 16V secondary, 2500Vrms isolation, through-hole laminated core

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 6VA TH
Key electrical rangeCurrent - Output (Max): Parallel 800mA, Series 400mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock0 pcs reported — confirm on RFQ

The real constraint is lifecycle, not the winding options

The constraint here is availability, not configuration. Discontinued status plus 0 stock ends the new-design discussion right away, so DST4-16B10 belongs only in existing production where the exact transformer is already on the board and a short-term buy still matters.

The electrical listing is coherent enough to show what it was built to do, but it does not change the sourcing position. Pulse lists EU RoHS compliance, which removes one compliance objection, yet the lifecycle call stands: don't start a fresh design around DST4-16B10.

Wrong for rail flexibility; right for a fixed low-VA mains stage

Wrong for any design that still needs flexibility on output voltage, mounting style, or mechanical envelope. The listing locks you into a through-hole laminated core with PC pins, no center tap, a 41.40mm x 33.27mm body, and 33.27mm max seated height, so if the board or enclosure is already tight, mechanical fit gets decided before the electrical side does.

It does fit a small mains-frequency supply that already expects dual primaries and dual secondaries. The 115V, 230V primary listing shows it can be wired for either input scheme, but that remains a configuration choice, not proof of universal mains coverage beyond those stated values.

On the secondary side, the listed ceilings are parallel 8V at 800mA max or series 16V at 400mA max. Those are winding limits, not operating targets, and they place DST4-16B10 in modest low-voltage rail work rather than loads that need extra current headroom or a center-tapped rectifier arrangement.

The 6VA maximum is the other hard boundary. Even if the voltage options line up neatly with the rest of the circuit, DST4-16B10 is still a small power part and should be treated that way.

2500Vrms isolation helps, but it doesn’t finish the review

2500Vrms is a meaningful isolation ceiling between windings. Useful, but incomplete.

It still leaves creepage, clearance, agency approvals, and insulation-system details unstated.

The missing items are the ones that decide release

And that is the problem beyond discontinuation: the listing stops before the details that usually settle a transformer choice. There is no pinout, no mechanical drawing beyond overall size, and no thermal data, so you cannot finish PCB placement, enclosure clearance, or temperature-rise judgment from this page alone.

The electrical gaps matter too. Regulation is absent, so secondary behavior away from full load remains unknown. There is no dielectric construction detail beyond the 2500Vrms isolation figure, and no mounting drawing to show pin spacing or hole pattern. Those are the items that would close the review fastest if you're trying to keep DST4-16B10 alive in an existing build.

View the Win-Source product page for DST4-16B10.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases; DST4-16B10 is discontinued and stock is 0.
  • Match the secondary exactly: parallel 8V at 800mA max or series 16V at 400mA max.
  • Reserve 41.40mm x 33.27mm footprint and 33.27mm seated height before touching the PCB.