6VA transformer with 115V/230V primary and 12V or 24V secondary options in through-hole form
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 6VA TH |
| Key electrical range | Current - Output (Max): Parallel 500mA, Series 250mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Stock is the weak point; the electrical fit is sound
The weak point comes first: listed stock is 0, so DST4-24B18 is not the answer for an urgent build. The stronger signal is lifecycle status. It is marked Active with no conflicting status fields, which keeps it in play for new design-in when the schedule can absorb a sourcing step.
Electrically, it sits in a well-defined slot. This is a through-hole, laminated-core power transformer rated 6VA, with dual primaries for 115V and 230V mains options and dual secondaries that can be wired for Parallel 12V or Series 24V. EU RoHS compliance removes one routine objection. It does not belong in cramped layouts or surface-mount-only assemblies.
And the 6VA ceiling is what keeps the use case honest
And that 6VA ceiling keeps the application narrow. It points to modest auxiliary rails and small linear supplies, while leaving thermal margin unanswered because no derating curve or thermal data is shown here.
The current figures are ceilings, not operating targets: 500mA with the secondary in Parallel 12V, 250mA with the secondary in Series 24V. The winding choice sets the rail plan early, not at the end of layout. The 2500Vrms isolation rating matters too, but it is still an isolation withstand figure rather than a statement about safety approvals or end-equipment qualification.
Board space, not status, decides whether it belongs
Board space is the real constraint here. A 41.40mm L x 33.27mm W footprint with 33.27mm maximum seated height takes room, and the 0.44 lb (199.58 g) weight points the same way. This is for anchored through-hole assemblies, not light daughtercards or mechanically fragile boards.
The dual-primary arrangement helps when one design must cover 115V and 230V input options without changing transformers. The secondary arrangement is simpler in one respect: center tap is explicitly No. That rules out a center-tapped rectifier scheme and keeps the fit focused on conventional low-power mains front ends where board area is available and assembly already expects PC pins.
2500Vrms helps, but the missing details still matter
2500Vrms is the decisive listed insulation figure. It is also not enough by itself to close implementation risk.
The missing details are concrete and important: pinout, mechanical drawing, and regulation data for the secondary under load. Without them, footprint work stalls, wiring review stays open, and rail tolerance expectations remain incomplete. Those are not minor omissions when the part is a board-level mains transformer with dual primaries and configurable secondaries, because the practical fit depends as much on lead arrangement and loaded behavior as it does on the headline voltage options.
Another gap matters just as much in release work. No inrush or surge-related current figure is shown, and no thermal resistance or derating information appears either. Those omissions affect fuse selection, startup stress, enclosure temperature, and whether the transformer still behaves acceptably once the nominal rail plan meets the actual product. For DST4-24B18, those are the first datasheet pages to open.
View the Win-Source product page for DST4-24B18.
Key Takeaways for Engineers & Buyers
- Lock the secondary wiring early: 12V in parallel or 24V in series changes the current ceiling to 500mA or 250mA.
- Reserve 41.40mm x 33.27mm footprint and 33.27mm height before committing the board stack.
- Treat 0 stock as the immediate blocker; place only against confirmed incoming supply.