6VA, 115V/230V primary, 14V parallel or 28V series secondary, through-hole laminated core
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 6VA TH |
| Key electrical range | Current - Output (Max): Parallel 400mA, Series 200mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Still a valid new design-in, if the board can carry it
And that is the real verdict on DST4-28B22: it remains a live part for a board-mounted mains transformer job, but only when 6VA is enough and the mechanical envelope already fits the product.
The deciding numbers are plain. The primary is 115V, 230V with dual windings, so this belongs in equipment that needs that mains flexibility at the transformer itself, not in a low-profile DC stage chasing a small magnetics footprint. The secondary is dual as well, with 14V in parallel or 28V in series, and the listed output current ceiling changes with that choice: parallel 400mA, series 200mA. Those are ceilings, not targets for routine operation, and getting the winding scheme wrong puts the rail plan or load budget off course before layout is done.
The package tells the same story. Through-hole mounting, PC pins, a laminated core, a 41.40mm by 33.27mm body, 33.27mm seated height, and 0.44 lb add up to a real chunk of iron on the board. It isn't subtle. If the design is cramped or height-limited, this part is out early; if the board can carry a conventional mains transformer and the power budget stays inside the listed limits, DST4-28B22 is still a workable new design-in.
The 6VA limit is the first thing that boxes you in
The constraint is capacity. The 6VA rating is a ceiling on what DST4-28B22 can deliver, and by itself it does not tell you thermal rise, ambient headroom, or how close you can run it in a sealed enclosure.
Set that beside the secondary options and the design space narrows fast. Full-load secondary is 14V in parallel or 28V in series, while output current is capped at 400mA in parallel or 200mA in series. Those figures settle the basic fit decision: small control supplies, modest analog rails, or housekeeping power are plausible, while anything needing startup surge tolerance, broad overload margin, or much more downstream current sits outside what this listing supports. The 2500Vrms isolation rating matters too, but it only sets the isolation ceiling stated here. It does not answer creepage, clearance, or agency-marking questions.
Wrong for low-profile builds, right for simple mains isolation
Not for dense, height-starved electronics. A 33.27mm seated height, through-hole pins, and a laminated core place DST4-28B22 squarely in old-school board power, where mechanical volume is available and the transformer provides straightforward mains isolation.
That is where it fits. Dual 115V, 230V primaries give flexibility for input configuration, and the dual secondary lets you choose 14V parallel or 28V series without a center tap, because there isn't one. That absence matters if the rectifier or split-rail scheme expects a center-tapped secondary; DST4-28B22 will not close that topology. If the design wants a compact switcher-era footprint, it is the wrong part. If it wants a conventional through-hole transformer with modest VA and a simple board interface, it is in bounds.
2500Vrms is useful, but the missing details are the hold-up
2500Vrms is the most decisive safety-facing figure in the listing, and it still is not enough to finish the part choice.
What is missing is concrete: pinout, mechanical drawing, and any thermal rise or derating information. The listing also does not give regulation behavior beyond the full-load secondary voltage, so off-load output movement remains unclear. For DST4-28B22, those gaps matter more than another recap paragraph because they decide board fit, wiring risk, and whether the transformer runs acceptably in the actual enclosure.
Buy against a schedule, not hope
Stock is the weak point. Active status and EU RoHS compliance are clean, but stock is 0, so demand needs to be tied to a dated order plan rather than spot availability.
View the Win-Source product page for DST4-28B22.
Key Takeaways for Engineers & Buyers
- Lock the secondary scheme early: 14V parallel or 28V series changes the rail and current ceiling.
- Reserve 41.40mm x 33.27mm footprint and 33.27mm height before committing the board stack.
- Plan the buy to demand; stock is 0 even though DST4-28B22 is Active.