Pulse DST4-36B26 active for new design-in

DST4-36B26 Pulse product image

6VA, 115V/230V primary, 18V parallel or 36V series secondary, 2500Vrms isolation, through-hole laminated core

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 6VA TH
Key electrical rangeCurrent - Output (Max): Parallel 340mA, Series 170mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock1 pcs reported — confirm on RFQ

Active status helps, stock does not

Use it for new design-in.

Active status is clear, with no lifecycle conflict. Supply is the catch: stock is 1 and package is Bulk, so production planning needs secured inventory before release.

6VA is the ceiling that keeps this transformer honest

6VA sets the limit.

That is the listed power ceiling, not an operating target, and it rules out loads that assume generous headroom from a general-purpose mains transformer.

Secondary choices are straightforward: 18V in parallel or 36V in series at full load, with current ceilings of 340mA in parallel or 170mA in series. Pick the wrong winding arrangement and the rail is wrong from the start. The 2500Vrms isolation rating matters too, but it only covers the isolation ceiling; it does not answer creepage, clearance, or safety approval questions because those details are not included here.

The weak point is missing fit detail, not the electrical idea

The fit detail is thin, but the electrical role is clear.

This is a through-hole laminated core transformer with PC pins, a 41.40mm L x 33.27mm W body, 33.27mm seated height, and 0.44 lb (199.58 g) of mass.

It fits low-power linear supplies, housekeeping rails, or isolated support power where 6VA is enough and through-hole assembly is acceptable. It does not fit height-constrained hardware. The no center tap note also matters when the rectifier scheme expects one. Dual primary and dual secondary windings give flexibility for 115V or 230V input and for 18V or 36V output, but they still leave you needing the pin map.

What the listing still doesn't tell you

Wrong for final layout release; right for early selection.

There is enough here to sort out category, voltage class, and rough board impact, but not enough to close the mechanical or compliance side of a mains transformer decision.

The missing items are concrete and important: pinout, mechanical drawing, and regulation behavior under load. Pinout comes first because dual primaries and dual secondaries only help when the PC pin assignments are known exactly. The drawing matters because 41.40mm by 33.27mm and 33.27mm height still do not tell you lead spacing, keepout, or hole pattern. Load regulation is also absent, and for a part specified at 18V parallel or 36V series full load, that missing behavior is what tells you how far the secondary rises at light load. Any one of those gaps can stop a board spin; here, there are three.

View the Win-Source product page for DST4-36B26.

Key Takeaways for Engineers & Buyers

  • Match the primary wiring to 115V or 230V before layout freeze.
  • Budget the secondary around 18V parallel or 36V series, with 340mA or 170mA as ceilings.
  • Hold release until pinout and mounting drawing for DST4-36B26 are in hand.