12VA, 115V/230V primary, 60V parallel or 120V series secondary, through-hole laminated core
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 12VA TH |
| Key electrical range | Current - Output (Max): Parallel 200mA, Series 100mA; Power - Max: 12VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Still useful only if the line already exists
And that is the whole call on DST5-120B39: not for a fresh design, only for sustaining builds that already have the mechanical space and wiring defined. Lifecycle Status is Discontinued, Product Status is Discontinued, and there is no conflicting signal to soften that reading. EU RoHS is fine, but compliance does not fix availability.
The electrical shape is narrow enough that a redesign around this part would be deliberate, not opportunistic. It is a laminated-core, through-hole transformer with dual primaries and dual secondaries, so it belongs in mains-frequency power sections already laid out for a board-mounted magnetic of this size. If your product already uses DST5-120B39, treat it as a sustaining part and move on a migration path.
The 12VA ceiling is what really constrains this part
Don’t push past it.
The number that settles most of the argument is 12VA. That is the listed maximum power, and it sets the budget for everything asked of the secondary. The winding options make that plain: 60V parallel at 200mA max, or 120V series at 100mA max. Those are ceilings tied to how the secondaries are connected, and they define where DST5-120B39 fits in a low-current high-voltage supply stage.
The primary side is just as specific. Dual primaries with 115V and 230V listed mean the transformer can be configured for either mains input scheme, but only with correct wiring; get that wrong and the problem is not lost margin but field failure. The 2500Vrms isolation rating sets a dielectric ceiling between primary and secondary, yet it still leaves creepage, clearance, and agency approval unanswered on its own, which is exactly why the part is easy to classify electrically and still incomplete for a fresh release.
47.24mm by 39.62mm makes it a board-space decision
47.24mm by 39.62mm is the footprint, and it drives the conversation before the schematic does. With 36.58mm seated height, through-hole mounting, PC pins, and 0.7 lb (317.51 g), this is plainly a board-mounted mains transformer for products that expect a laminated core on the PCB, not a compact supply where height and mass are already tight.
The lack of a center tap narrows the fit further. Dual secondaries give series or parallel options, but not a center-tapped topology from the listed configuration. That makes DST5-120B39 sensible for straightforward isolated rails at 60V or 120V, and a poor fit when the power tree assumes a center-tapped secondary or the mechanical stack cannot absorb this footprint and height.
Can you actually buy DST5-120B39 now?
Can you buy it now? No. Stock quantity is 0, package is Bulk, and the part is discontinued. For an existing production line, stop treating DST5-120B39 as a reorderable standard item and treat every remaining unit in your own stores as controlled inventory.
What the listing still doesn’t answer
Wrong for a release package that needs mechanical and safety detail; acceptable only as a quick triage view. The missing items that matter are the pinout, a mechanical drawing, and temperature-rise or thermal data.
View the Win-Source product page for DST5-120B39.
Key Takeaways for Engineers & Buyers
- Block new BOM releases on DST5-120B39; lifecycle is Discontinued.
- Check board height and footprint against 36.58mm max and 47.24mm x 39.62mm body size.
- Match the secondary wiring to the load: 60V parallel at 200mA max or 120V series at 100mA max.