12VA, 115V/230V primary, 14V parallel or 28V series secondary, through-hole laminated core
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 12VA TH |
| Key electrical range | Current - Output (Max): Parallel 840mA, Series 420mA; Power - Max: 12VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 0 pcs reported — confirm on RFQ |
The real limit is 12VA, not the winding count
The constraint is the 12VA ceiling. Dual primary and dual secondary windings make DST5-28B23 flexible, but they do not change the listed power limit or let the current figures stand alone as independent operating targets.
Read the secondary ratings as paired options: 14V at parallel 840mA, or 28V at series 420mA. That settles the winding choice quickly, and if your rail plan needs some other secondary arrangement, this is the wrong transformer. It does not settle thermal behavior, because no temperature-rise, derating, or regulation figure is given, and those missing numbers are what separate a nominal match from a transformer that will actually behave in the build. The 2500Vrms isolation rating is also a ceiling, useful for insulation coordination and safety spacing, but it says nothing about normal output behavior under load.
Active status helps; zero stock doesn’t
New design-in is reasonable.
Active status removes the lifecycle objection. The immediate issue is supply: stock quantity is 0, and the package is Bulk. That puts DST5-28B23 into planned procurement rather than opportunistic replenishment, so it belongs on the BOM only when supply can be lined up against the build schedule. EU RoHS is straightforward and doesn't complicate that decision.
Wrong for low-profile boards, right for mains iron
Wrong for compact, low-profile boards.
It fits through-hole mains power sections where a laminated core, PC pins, a 47.24mm x 39.62mm footprint, and 36.58mm height are acceptable. Weight is 0.7 lb. No center tap narrows the fit further.
And the missing numbers are the ones that finish the call
And that is where the listing stops being enough. There is no regulation figure, so secondary movement from no-load to full-load is still unknown. There is no temperature-rise or derating information, so ambient headroom remains open. There is no pinout or mechanical drawing in the listing, leaving board escape and hole pattern unresolved.
Those are the details that finish the call. On a transformer, they decide whether the part merely matches the nominal rail and VA line or actually lands cleanly in the enclosure and survives the thermal environment.
View the Win-Source product page for DST5-28B23.
Key Takeaways for Engineers & Buyers
- Match the secondary exactly: 14V in parallel or 28V in series changes the downstream rail.
- Reserve board area for 47.24mm x 39.62mm and 36.58mm seated height before layout freeze.
- Plan supply early; stock is 0 even though DST5-28B23 is active.