36VA, 115V/230V primary, 5V or 10V secondary, 2500Vrms isolation, through-hole laminated core
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 36VA TH |
| Key electrical range | Current - Output (Max): Parallel 7.2A, Series 3.6A; Power - Max: 36VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Use it for new builds, not for urgent demand
Good part.
Lifecycle status is active, and the signals agree, so there is no status conflict blocking a new design-in. Supply is the catch: listed stock is 1, which makes this a poor choice for any build that needs immediate continuity. EU RoHS is compliant.
As a through-hole laminated power transformer with dual primary and dual secondary windings, DST7-10B51 fits designs that already want that construction. If your sourcing window is tight, it isn't the part to lean on.
The current numbers are ceilings, not free output
The weak point comes first: 36VA sets the limit. The listed 7.2A in parallel and 3.6A in series are maximum output figures tied to the 5V and 10V full-load secondary options.
Wrong for low-profile boards, right for mains iron
Not for compact or height-starved layouts. This is a 66.80mm x 55.63mm, 39.62mm-high, 1.1 lbs (499 g) through-hole laminated transformer with PC pins, so it belongs on boards laid out for real mains magnetics, not on dense low-profile assemblies where height, mass, and hole pattern all push back at once.
It fits board-mounted supplies that need either 115V or 230V primary support and a simple low-voltage secondary choice: 5V in parallel or 10V in series at full load. No center tap matters here. That rules out center-tapped rectifier schemes without rewiring tricks, a small detail that can save a board spin when someone assumes a more flexible secondary than the part actually offers.
One number matters most on the buy side
Stock quantity 1 is the constraint. It says nothing about the electrical merit of DST7-10B51, but it does decide how you use it: fine for qualification, bench work, or a scheduled build with secured supply, and a bad bet for an open production release.
Packaging is bulk. For a part like this, that points to manual handling and board-level receiving discipline rather than any assumption of feeder-ready presentation.
2500Vrms helps, but the missing details still decide the review
2500Vrms is the listed isolation ceiling, and it places DST7-10B51 in the class of transformers meant to separate primary from secondary in a real mains supply. Useful, yes, but not enough by itself, because creepage, clearance, insulation system, and safety-approval details still decide whether the part clears compliance review in the product around it.
The missing items are concrete. There is no pinout here, so schematic symbol mapping and PCB placement cannot be finished from this page. There is no mechanical drawing beyond overall size and height, leaving hole pattern and lead spacing unresolved. There is no temperature rise, thermal class, or derating curve, so the 36VA figure stays a ceiling without the ambient context that determines enclosure headroom.
There is also no inrush or similar surge-handling detail, and that gap matters because laminated mains transformers can stress upstream protection long before steady-state numbers look troublesome.
View the Win-Source product page for DST7-10B51.
Key Takeaways for Engineers & Buyers
- Lock the winding configuration early: parallel gives 5V and 7.2A, series gives 10V and 3.6A.
- Reserve vertical space for 39.62mm height and board area for 66.80mm x 55.63mm footprint.
- Treat stock quantity 1 as a line-stop risk; place DST7-10B51 only on scheduled builds.