Pulse DST7-120B60 active, but buy only for matched builds

DST7-120B60 Pulse product image

36VA, 115V/230V primary, dual 60V or 120V secondary, 2500Vrms isolation, through-hole laminated core

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 36VA TH
Key electrical rangeCurrent - Output (Max): Parallel 600mA, Series 300mA; Power - Max: 36VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock1 pcs reported — confirm on RFQ

Not for compact boards; right for fixed mains iron

This is the wrong transformer for space-tight boards or weight-sensitive assemblies. At 66.80mm x 55.63mm with a 39.62mm seated height and 1.1 lbs (499 g) mass, it belongs in equipment that already expects a laminated through-hole mains transformer, not in anything trying to disappear into a low-profile enclosure.

In the right build, the fit is simpler. The 115V, 230V dual primary covers two common input options, and the dual secondary can be wired as parallel 60V or series 120V. No center tap is listed, so any design that depends on a center-tapped secondary is out. Active lifecycle supports new design-in, and EU RoHS compliance removes a common approval snag.

36VA is the ceiling that keeps the rest honest

36VA sets the boundary for the whole part. It is a ceiling, not a target, and it has to cover the secondary arrangement you actually plan to use rather than the one that looks cleaner on the schematic.

The secondary options make the trade plain. In parallel, the listing is 60V and 600mA max; in series, it is 120V and 300mA max. Those are output limits tied to how the windings are connected, so the choice is real: lower voltage with higher current, or higher voltage with lower current. You do not get both at once, and if that distinction gets blurred in the design, the transformer becomes the first hard limit in the build instead of the load.

The 2500Vrms isolation rating matters too, but in a narrower way than the headline suggests. It sets the listed primary-to-secondary withstand level, while leaving board creepage, fuse choice, and surge behavior to the finished design. The dual primary also broadens where the part can be used, since 115V and 230V are both listed, yet the page still stops short of the details needed to finish the connection work because it does not show the exact wiring scheme or pinout.

The weak point is supply, not status

Only 1 unit is listed. That's the real constraint.

Active status helps, but immediate availability is what blocks use in production. Put it on a running line only after supply is secured.

2500Vrms helps, but the missing drawing still matters

2500Vrms is useful, but it does not close the review. The missing items are concrete ones: pinout, mechanical drawing detail beyond overall size, and primary-to-secondary wiring information for the dual windings.

Regulation data and thermal rise data still matter because 36VA alone does not show how the secondary voltage shifts from no-load to full-load or how hot the transformer runs in a closed box. Those gaps are the difference between a plausible fit and a released layout.

View the Win-Source product page for DST7-120B60.

Key Takeaways for Engineers & Buyers

  • Lock the PCB and enclosure to 66.80mm x 55.63mm x 39.62mm before releasing DST7-120B60.
  • Choose the secondary wiring up front: parallel 60V at 600mA max or series 120V at 300mA max.
  • Treat stock of 1 as a line-stop risk; place DST7-120B60 only on builds with secured supply.