Pulse DST7-24B55 discontinued, sustaining use only

DST7-24B55 Pulse product image

36VA, 115V/230V primary, 12V or 24V secondary, through-hole laminated core, 2500Vrms isolation

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 36VA TH
Key electrical rangeCurrent - Output (Max): Parallel 3A, Series 1.5A; Power - Max: 36VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Reported stock0 pcs reported — confirm on RFQ

36VA decides the verdict before anything else

36VA sets the tone. It does not change the lifecycle outcome for DST7-24B55.

The transformer supports a modest mains-frequency power stage, with dual primaries for 115V or 230V input and dual secondaries used as 12V in parallel or 24V in series, but the part is discontinued and stock is 0, so new design-in stops there.

For existing production, DST7-24B55 still reads as a sustaining part when the schematic already matches its winding options and mechanical envelope. EU RoHS is listed as compliant, so compliance is not the blocker. Availability is.

The real constraint is current only in the stated winding mode

Current is limited by winding mode. The listed output current is a ceiling: 3A in parallel and 1.5A in series. Read that alongside the secondary voltage options of 12V parallel and 24V series, because the winding arrangement determines whether the part fits the design at all.

The 2500Vrms isolation rating is also a ceiling, not a statement about creepage on the assembly or system safety approval. It places the transformer in offline power hardware, while the dual-primary 115V and 230V listing covers line-voltage fit. What is still missing is the connection detail for how those primaries are strapped, and that matters.

Wrong for low-profile boards, right for old-school through-hole mains iron

Wrong for compact or height-limited layouts. Right for a through-hole board that already expects a laminated-core transformer with PC pins, a 66.80mm x 55.63mm body, and 39.62mm maximum seated height.

What would actually close the open technical questions?

What would you need first to buy with confidence? A pinout.

That missing detail decides whether DST7-24B55 can drop into an existing design without rework, because you cannot confirm primary and secondary phasing or how the dual windings are meant to be strapped for 115V, 230V, 12V, or 24V use.

There is also no drawing beyond body size and height, no thermal data, and no regulation figure showing how the secondary moves from no-load to full-load. For a mains transformer, those gaps decide hole pattern, enclosure clearance, and whether the downstream rail still lands where the circuit expects it.

View the Win-Source product page for DST7-24B55.

Key Takeaways for Engineers & Buyers

  • Lock the build around 115V or 230V primary selection before touching the PCB.
  • Keep secondary use inside the listed 12V parallel or 24V series configurations.
  • Treat 39.62mm height and 66.80mm x 55.63mm body size as enclosure gates.