12-position free-hanging crimp receptacle with IP68/IP6K9K features and -55°C to 125°C range
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TE Connectivity |
| Category | Rectangular Connector Housings |
| Package | Bulk |
| Core function | DT RECP ASM |
| Key electrical range | Operating Temperature: -55°C ~ 125°C |
| Reported stock | 1 pcs reported — confirm on RFQ |
Still, the real call is yes for new harness work
Still, the real call is yes for new harness work. DT04-12PC-CE08 is marked Active twice, with no lifecycle conflict, so nothing here pushes it into sustaining-only territory.
The hold-up is paperwork and supply, not lifecycle. The RoHS story splits between RoHS Compliant and RoHS Non-Compliant, so compliance is not settled. Stock also splits between 1 and 75. That leaves DT04-12PC-CE08 viable for new design-in, but only after the compliance contradiction is cleared and material is reserved against the actual build.
What decides the fit first: sealing, temperature, or layout?
What would a buyer ask first: will it fit the harness and survive the environment? Here, layout and sealing answer that faster than anything else.
The housing is a free hanging, in-line receptacle with 12 positions in 2 rows, crimp termination, and male pin contacts. That settles one major decision right away: it belongs in a cable-to-cable or cable-end harness interface, not on a board and not in any design expecting a soldered termination.
The environmental numbers keep it in consideration, but they are ceilings, not proof of electrical margin. The listed operating range is -55°C to 125°C. That supports designs exposed to cold start and hot enclosure conditions, yet it says nothing about current rise, contact heating, or derating under load because those figures are not here.
Sealing is the other big filter. IP68 and IP6K9K, along with reduced wire seals and enhanced keying, point this housing toward exposed harness runs where water ingress, washdown, or mis-mating risk are real concerns. It is built for harsh interconnect duty.
That still does not close the review. The listing does not give mating connector details, cavity dimensions, or wire-size acceptance, so you cannot tell from this page alone whether existing harness tooling and seals will fit. Fastening type matters too: a latch holder is a retention choice, not a vibration qualification by itself, and that distinction matters once installation loads and service handling start working on the harness.
Wrong for boards; right for sealed inline harnesses
Not for board-mounted interconnects. Not for any assembly that needs a finished connector with contacts already installed, either, because DT04-12PC-CE08 is a housing with crimp termination called out, not a complete terminated cable end.
Where it fits is a sealed inline harness interface that needs 12 positions, 2 rows, and a receptacle body with keying and latch retention. The green housing color can matter in service environments where visual identification is part of assembly control. DT04-12PC-CE08 makes sense when the connector body, sealing features, and harness form factor are the design problem. It does not answer contact selection, wire range, or mating geometry on its own.
The gaps are mechanical, not lifecycle
The weak point is the missing detail. DT04-12PC-CE08 still needs the cavity layout, mating-part callout, wire-size acceptance, and housing drawing to close a real connector review.
View the Win-Source product page for DT04-12PC-CE08.
Key Takeaways for Engineers & Buyers
- Lock the BOM to a 12-position, 2-row free-hanging receptacle before releasing harness drawings.
- Resolve the RoHS conflict now; one field says compliant and another says non-compliant.
- Secure stock before build scheduling; quantity is listed as 1 in one place and 75 in another.