125°C operation and IP68/IP6K9K are listed, but contact, mounting, and position details still conflict
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TE Connectivity |
| Category | Rectangular Connectors |
| Package | OM780-4 |
| Core function | CONN RCPT HSG 6POS |
| Key electrical range | Not listed for this part |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you design DT04-6P-E004 into a new harness?
Can this go into a new harness without drama? Yes, if you clear the mechanical contradictions first. DT04-6P-E004 is marked Active, with no lifecycle conflict, and the EU RoHS status removes one routine compliance objection.
The real blocker is fit data. The listing calls it CONN RCPT HSG 6POS, while one specification says Number of Positions: 5 and the row data says 5 + 2; the alternate detail set says 6 positions and 3 rows. It is also described as a receptacle housing with female socket in one place and with male pin contacts in another, and those conflicts decide mating compatibility, harness layout, and whether DT04-6P-E004 belongs on your BOM at all.
Wrong for board mounting, right for sealed cable interconnects
Not for a PCB. The through-hole mounting entry points one way, but the alternate detail set says free-hanging and crimp termination, which fits a cable-side housing far better than a board-mounted connector.
That distinction matters more than the generic category name. A spring lock, receptacle form, and stated IP68 and IP6K9K features point to the kind of interconnect where sealing, latch retention, and mating geometry decide success. If your design needs a wire-to-wire or wire-to-device sealed housing, this looks plausible. If you need a connector you can place, solder, and inspect on a PCB, the current listing does not support that use and may mislead the layout team.
Buy it only after the fit data is reconciled
Stock is the constraint.
One stock field shows 1, while another quantity field shows 4991, and those two numbers lead to very different actions. Treat DT04-6P-E004 as available but not yet line-safe for an immediate build plan until the sellable quantity is confirmed in the channel you will actually use. Packaging also conflicts between OM780-4 and bulk, which matters if your line depends on a specific handling flow rather than loose housings.
125°C helps, but the missing drawing still decides the part
125°C is useful, not sufficient. The alternate detail set gives an operating temperature of -55°C to 125°C, which closes one important question: DT04-6P-E004 belongs in environments much harsher than indoor commercial electronics. It does not settle the sealing or retention decision, because temperature range is an operating limit, not proof that the housing geometry, terminal system, and mating half are right for your assembly.
The IP68 and IP6K9K features push in the same direction. They say the housing is meant for sealed service, where water ingress and washdown exposure are design concerns, but they do not tell you what seal arrangement, cavity layout, or mating connector is required to achieve that result in your build.
The drawing is the biggest gap, followed by a clear pin or cavity layout, a definitive contact gender statement, and one authoritative position count. Without those items, DT04-6P-E004 remains a candidate rather than a released choice, because those missing mechanical facts are exactly what prevent wrong-mate errors and harness rework.
View the Win-Source product page for DT04-6P-E004.
Key Takeaways for Engineers & Buyers
- Resolve whether DT04-6P-E004 is 5 positions or 6 before release.
- Confirm free-hanging versus through-hole mounting from the housing drawing.
- Check the mating half and keying; spring lock alone does not close fit.