Diodes Incorporated DT2042-04SO-7 for new design-in

DT2042-04SO-7 Diodes Incorporated product image

5.5V stand-off, 10.5V clamp, 10A pulse, 4 channels, SOT-26, -55°C to 85°C

Quick Engineering Summary

FieldValue
ManufacturerDiodes Incorporated
CategoryTVS - Diodes
PackageSOT-26
Core functionTVS DIODE 5.
Key electrical rangeMax Clamping Voltage: 10.5V; Minimum Breakdown Voltage: 6V; Peak Pulse Current(Ippm): 10A (8/20μs); Power Dissipation - Pd: 105W
Reported stock398000 pcs reported — confirm on RFQ

Not for high-voltage rails; right for dense 5V-class protection

Don't use this on anything that normally sits above 5.5V. That 5.5V stand-off is the ceiling for normal reverse standoff, so higher-voltage rails are out from the start.

Where it does fit is low-voltage line protection that needs density more than brute surge muscle. DT2042-04SO-7 is a steering, rail-to-rail TVS with 4 unidirectional channels in SOT-26, and that combination points to compact boards where saving space matters. The 10.5V max clamping voltage and 6V minimum breakdown voltage also set the tone: during a hit, the protected node can still move a fair amount, which can work on tolerant logic or power-adjacent signal lines but rules it out for tighter interfaces that need lower let-through behavior.

The lifecycle and compliance signals support using it in current designs. Active status and EU RoHS are straightforward positives. Even so, the part belongs on compact boards that need multi-line protection in a small package, not on rails or ports that need a lower clamping ceiling, a wider operating rail, or more surge headroom than a 10A, SOT-26 device can offer.

10A is the number that keeps this honest

10A (8/20μs) is the decisive limit. It is a peak pulse current ceiling, not a statement about repetitive stress or longer surge waveforms, and it marks the point where DT2042-04SO-7 stops being the right protection part.

Set that beside the 105W power dissipation listing and the 10.5V max clamping voltage, and the real question becomes whether the surge case stays inside those transient limits without asking a small SOT-26 body to absorb more than it is rated to take. Short sentence, big consequence.

The -55°C to 85°C operating range matters too, because ambient use above 85°C at TA is outside the listed range. What you still do not get here is junction rise, derating, or thermal margin during repeated events.

Buy it for current builds, but buy it in reels

This one is buyable.

Packaging is the practical constraint, not lifecycle. DT2042-04SO-7 is listed as Reel - TR with 398000 in stock, which fits volume SMT assembly and sustaining demand better than hand-load scenarios. If it is going onto a running line, keep the reel format in the AVL and avoid creating a second handling path for the same SOT-26 device.

Supply and demand is marked Balance, and lifecycle is Active. Commercial risk reads low.

The missing data is exactly what closes the interface call

The weak point is the missing interface detail, even though the headline limits are usable. For DT2042-04SO-7, the listing does not give junction capacitance, and that omission can decide the part on fast or sensitive signal paths before any other number does.

Other gaps are just as concrete: no pinout, no package drawing, no thermal resistance, and no reverse-recovery figure. Without the pin map and drawing, board fit is still incomplete even with SOT-26 named. Without thermal resistance, the 105W pulse figure remains only a transient ceiling. Without reverse-recovery data, the behavior of this steering device on the exact line you want to protect is still unresolved.

View the Win-Source product page for DT2042-04SO-7.

Key Takeaways for Engineers & Buyers

  • Keep DT2042-04SO-7 on rails that stay within 5.5V in normal operation.
  • Check surge cases against the 10.5V clamping ceiling and 10A (8/20μs) pulse limit.
  • Lock reel usage and feeder setup for SOT-26, Reel - TR before release.