50 V, 100 mA, 200 mW ceilings in UMT3 SC-70/SOT-323 set the limits for this pre-biased PNP.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Rohm Semiconductor |
| Category | Transistors (BJT) - Single, Pre - Biased |
| Package | Tape & Reel |
| Core function | TRANS PREBIAS PNP 50V 0. |
| Key electrical range | Current - Collector (Ic) (Max): 100 mA; Current - Collector Cutoff (Max): 500nA (ICBO); DC Current Gain (hFE) (Min) @ Ic, Vce: 100 @ 1mA, 5V; Frequency - Transition: 250 MHz |
| Reported stock | 350 pcs reported — confirm on RFQ |
The package is small; the ceilings are smaller
The constraint is simple: 100 mA collector current max and 200 mW power max in UMT3 narrow the job faster than the 50 V headline does. Those two ceilings put DTA114TU3T106 in signal switching and biasing work, not in anything expected to absorb much fault energy or run near its limits for long.
The call is clear. It is a valid new design-in part for compact pre-biased PNP stages, and the lifecycle picture is clean at Active with no conflict. The 50 V collector-emitter breakdown decides whether the rail is even eligible, but it does not say how much current or heat the device can carry on that rail over time. Use it where the integrated resistor network cuts parts count, not where you need current headroom.
Wrong for load switching, fine for compact bias stages
Wrong for load switching. The 100 mA Ic max and 200 mW max shut that down quickly.
It fits dense board-level control, level shifting, and simple high-side PNP switching where the built-in 10 kOhms base resistor is the reason to use the part.
350 pieces is enough for a line check, not a broad release
350. That is the visible stock quantity, and it frames the immediate supply question.
For DTA114TU3T106, Tape & Reel packaging and Active lifecycle status point away from EOL risk. The practical issue is whether 350 covers your build window; if not, lock supply before release. MSL 1 (Unlimited) helps on the floor, but it does nothing for quantity risk.
Two transistor numbers matter more than the frequency line
50 V is the first gate. If collector-emitter stress can exceed that breakdown ceiling, DTA114TU3T106 is out before the rest of the discussion starts.
After that, the more useful figure is Vce saturation max at 300mV @ 1mA, 10mA. It is a ceiling at a stated test point, not a promise of low drop everywhere, and it places the characterization squarely in small-signal territory rather than heavy switching. The hFE minimum of 100 @ 1mA, 5V points the same way: low-current control work, modest loads, and predictable biasing around the built-in resistor. The 250 MHz transition frequency is worth noting, but without capacitance data or switching-time data, it does not settle a fast-edge design decision on its own.
The missing details are exactly the ones that close the review
What would you need to check first before release? The internal network and the package details.
The published resistor value only gets you partway there. DTA114TU3T106 lists R1 at 10 kOhms and does not list an emitter resistor R2, so the full datasheet is still needed to confirm the actual bias topology before you commit a logic interface or turn-off behavior.
The package naming is not enough by itself, either. There is no pinout here, so you cannot do a footprint-to-function check from this page alone even though the package is identified as SC-70, SOT-323, and UMT3. There is no package drawing, so land pattern and orientation still depend on the datasheet.
The dynamic picture is also unfinished. There are no switching-time figures and no junction capacitance figures, and those are the numbers that decide whether DTA114TU3T106 behaves cleanly in edge-sensitive signal paths rather than merely staying inside its voltage and current ceilings.
View the Win-Source product page for DTA114TU3T106.
Key Takeaways for Engineers & Buyers
- Keep VCE below the 50 V breakdown ceiling; that number sets rail eligibility, not operating margin by itself.
- Treat 100 mA collector current and 200 mW power as coupled ceilings in UMT3; they close off load-driving jobs fast.
- Confirm the internal bias network is acceptable: this DTA114TU3T106 lists only R1 at 10 kOhms and no R2.