ON Semiconductor DTA114YET1 discontinued, sustaining only

DTA114YET1 ON Semiconductor product image

50 V, 100 mA, 200 mW in SC-75/SOT-416; package size and lifecycle settle it quickly.

Quick Engineering Summary

FieldValue
ManufacturerON Semiconductor
CategoryTransistors (BJT) - Single, Pre - Biased
PackageTape & Reel
Core functionTRANS PREBIAS PNP 50V 0.
Key electrical rangeCurrent - Collector (Ic) (Max): 100 mA; Current - Collector Cutoff (Max): 500nA; DC Current Gain (hFE) (Min) @ Ic, Vce: 80 @ 5mA, 10V; Power - Max: 200 mW
Reported stock216000 pcs reported — confirm on RFQ

So this is sustaining stock, not a fresh design choice

And that settles the main decision. The lifecycle is discontinued, with an EOL signal in the same record, so new design-in is off the table even though EU RoHS is compliant and stock shows 216000.

Can you still buy it for a running line?

Can we still get enough to cover a bridge build? Yes, if the need is specific and time-bounded. Stock shows 216000 on hand, packed as Tape & Reel with a standard package of 3,000 pcs, which fits a production bridge better than ad hoc repair demand.

What that does not buy you is continuity. DTA114YET1 is discontinued, so buy only against existing production demand, lock the reel count you actually need, and keep it out of any new assembly where the next shortage becomes your problem.

The 200 mW ceiling matters more than the 50 V headline

The constraint is heat, not voltage. DTA114YET1 is a PNP pre-biased transistor in SC-75, SOT-416, and the appeal is clear: the transistor and bias network are already inside, with R1 at 10 kOhms and R2 at 47 kOhms, so the footprint stays small and placement gets simpler.

The listed limits are ceilings, not operating targets. The 50 V collector-emitter breakdown rating answers one question: whether your rail can ever force the device past that voltage. It does not say how comfortably the part behaves near that ceiling, and it says nothing about switching speed or transient stress. The 100 mA collector rating is a ceiling too. It rules out loads that need more collector current, but by itself it does not prove the package can shed the heat your use case creates.

That leaves the 200 mW maximum power rating as the number that really shapes the decision, because in a pre-biased transistor this small, dissipation usually ends the conversation before voltage does, especially when the circuit spends time in saturation instead of making a clean on-off transition. The only saturation point listed is 250mV @ 300µA, 10mA. That is useful if your intended load current sits near that point, but it does not close the case for heavier current because no broader curve is given.

The gain figure is just as narrow: hFE is 80 @ 5mA, 10V. Useful at that test point. If the design depends on predictable behavior far from 5mA or at a very different Vce, this page does not support that argument for DTA114YET1.

Good for resistor-saving logic loads, not power switching

Use it for small jobs. A PNP pre-biased device with 10 kOhms and 47 kOhms fits compact level shifting, simple inverter stages, and load control where board area matters more than current headroom.

Do not treat it like a power transistor. SC-75, SOT-416 and a 200 mW ceiling put DTA114YET1 in housekeeping duty, not in anything that lives near the 100 mA limit for long or sees ugly collector transients.

The missing curves are the real review stopper

200 mW is the clue that the missing thermal detail matters. There is no pinout or package drawing here, so footprint and orientation still need the datasheet. There is no thermal resistance or derating curve, which is exactly what sets ambient headroom against the 200 mW ceiling. There is no switching-time data, so if DTA114YET1 needs to move quickly rather than just switch eventually, this listing does not answer that.

View the Win-Source product page for DTA114YET1.

Key Takeaways for Engineers & Buyers

  • Block DTA114YET1 from new BOM releases; lifecycle is discontinued.
  • Check collector load against the 100 mA ceiling and the 200 mW ceiling together.
  • Confirm the built-in bias network fits the drive scheme: R1 is 10 kOhms and R2 is 47 kOhms.