50V VCEO ceiling, 30mA collector limit, 300mW dissipation, SPT through-hole pre-biased PNP
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Rohm Semiconductor |
| Category | Transistors (BJT) - Single, Pre - Biased |
| Package | SPT |
| Core function | TRANS PREBIAS PNP 50V 0. |
| Key electrical range | Collector Cut-off Current(Max): 500nA; Frequency - Transition: 250MHz; Maximum Current Collector: 30mA; Maximum Power Dissipation: 300mW |
| Reported stock | 1 pcs reported — confirm on RFQ |
50V is useful, but EOL ends the design-in argument
50V is the decisive number at first glance. It is the VCEO ceiling, so DTA144ESATP can sit on higher-voltage small-signal rails than many logic-side pre-biased transistors.
That still does not make it a candidate for a new program. Lifecycle is EOL, stock is listed at 1, and that combination settles the question fast. Keep it only for existing production that already depends on the built-in resistor network and package fit. For anything new, choose a live part instead.
EU RoHS compliance helps sustaining builds. It doesn't change the lifecycle outcome.
Can you still buy enough to matter?
Can you get enough parts to support production? Not really.
Listed stock is 1, and with DTA144ESATP already marked Obsolete(EOL), purchasing shifts from normal replenishment to line support. Reserve any remaining demand for service builds or a short sustaining run, then move the BOM off DTA144ESATP.
AMMO PACKAGE and through-hole mounting show it was aimed at insertion flow rather than loose prototype use, but that is secondary. Availability is the stop sign.
The real fit is low-current switching with fixed bias
The constraint is fixed bias. R1 is 47k and R2 is 47k, and those built-in values define where DTA144ESATP works cleanly and where it becomes awkward.
That resistor pair is the reason to use the part at all: it removes two external resistors and fixes the base-drive behavior at the transistor. In a circuit already built around those assumptions, the part can simplify a very specific low-current interface. In a circuit that needs different bias conditions, the same network becomes a hard limitation.
Current is the next boundary. The 30mA maximum collector current is a ceiling, not a target, so this belongs in signal switching, small enables, and light loads. It does not belong in relay-class or lamp-class current.
Power closes the window further. The 300mW maximum power dissipation is also a ceiling, and it rules out casual use where saturation loss or ambient heat is already tight, especially since this listing does not include a derating curve to show how quickly that margin shrinks in real assembly conditions.
One test condition gives a little more shape to the fit. VCE(sat) is 300mV max at 500µA and 10mA, which points to modest collector-current switching without a large saturation penalty at that stated point. The 68 minimum hFE at 5mA, 5V supports the same read.
In practice, DTA144ESATP fits low-current through-hole control paths where the fixed 47k/47k network is exactly what the circuit wanted.
The missing items are the ones that close the review
The weak point is documentation depth. The headline limits are clear enough, but the missing items that matter are concrete: pinout, package drawing, thermal derating information, switching-time data, and thermal resistance.
Without those, you cannot finish footprint release, judge ambient dissipation with confidence, or pin down timing behavior from this page alone.
There is also no transient current figure such as IFSM-equivalent surge handling for misuse cases. That leaves DTA144ESATP usable mainly in a known sustaining design, where the unanswered details are already resolved elsewhere.
View the Win-Source product page for DTA144ESATP.
Key Takeaways for Engineers & Buyers
- Block DTA144ESATP from new BOMs; lifecycle is EOL.
- Check collector load against the 30mA ceiling before using remaining stock.
- Confirm the fixed 47k/47k bias network matches the drive logic; those resistor values are not adjustable.