Rohm Semiconductor DTB123YCHZGT116 for new design-in

DTB123YCHZGT116 Rohm Semiconductor product image

500 mA collector ceiling, 200 mW power ceiling, SST3 package, pre-biased PNP with 2.2 kOhms and 10 kOhms built in

Quick Engineering Summary

FieldValue
ManufacturerRohm Semiconductor
CategoryTransistors (BJT) - Single, Pre - Biased
PackageTape & Reel
Core functionTRANS PREBIAS PNP 0.
Key electrical rangeCurrent - Collector (Ic) (Max): 500 mA; DC Current Gain (hFE) (Min) @ Ic, Vce: 56 @ 50mA, 5V; Frequency - Transition: 200 MHz; Power - Max: 200 mW
Reported stock1 pcs reported — confirm on RFQ

The power ceiling is tighter than the current headline

The real constraint is dissipation, not the 500 mA headline. DTB123YCHZGT116 is an Active pre-biased PNP, and the listed 200 mW maximum is the ceiling that decides whether it stays in a small-signal switch position or runs out of thermal room before the collector-current limit matters.

The 500 mA collector rating does not make it a comfortable half-amp workhorse in every case; it only answers one question about absolute current capability. More useful for switching is the 300mV Vce(sat) maximum at 2.5mA and 50mA, because that gives a concrete conduction-loss reference at the stated test point while leaving higher-load behavior unanswered. EU RoHS is compliant, and the AEC-Q101 series callout gives DTB123YCHZGT116 credibility for automotive-qualified sourcing when the rest of the design supports it.

Those built-in resistors decide the circuit more than hFE does

That is why the internal network matters more than the transistor label. DTB123YCHZGT116 is not a generic PNP you can bias any way you like; the 2.2 kOhms base resistor and 10 kOhms emitter-base resistor are fixed, so they set how hard a logic node can drive it, how quickly the base is bled off, and whether the surrounding resistor network disappears cleanly or ends up fighting the built-in values.

The minimum hFE of 56 at 50mA and 5V is a bounded point, not a blanket promise across the load range. It helps when intended collector current sits near that condition, but it does not settle startup behavior, deep saturation away from the test point, or leakage-sensitive biasing. The 200 MHz transition frequency says the device is not inherently slow, yet it still leaves real switching loss unresolved because no storage time or reverse-recovery style switching data is listed.

In practice, DTB123YCHZGT116 fits compact high-side or pull-up switching stages that want a pre-biased PNP in SOT-23-class real estate and can live with the resistor pair Rohm chose. It is a poor fit for designs that need custom base-drive shaping, very low standby leakage analysis, or a broad safe-operating picture from a short listing, because the fixed resistor values and missing voltage limits leave too much undecided.

200 mW is the number that keeps this in small-signal territory

200 mW is the decisive figure. In an SST3, TO-236-3, SC-59, SOT-23-3 footprint, that ceiling keeps DTB123YCHZGT116 in compact switching and biasing roles, not in jobs where the package is expected to absorb sustained dissipation just because the collector rating reads 500 mA.

The package is a strength when board area is tight and assembly is standard surface mount. MSL 1 (Unlimited) helps on floor life, and tape and reel suits volume assembly. The buy-side problem is simpler: listed quantity is 1. For a prototype, fine. For a running line, secure actual reel supply before DTB123YCHZGT116 goes onto an approved build list.

The missing voltage and thermal data still block release

Good candidate, incomplete listing.

The biggest gap is the collector-emitter voltage limit. That number decides rail fit before anything else. Thermal resistance is also absent, so the 200 mW ceiling cannot be tied to board temperature rise from this page alone. No pinout or package drawing appears here either, which matters because pre-biased transistors are easy to misplace when the internal resistor network is part of the function.

One more omission matters for switching work: no collector cutoff current is listed. For low-leakage or battery-held nodes, that missing number can decide whether DTB123YCHZGT116 is harmless when off or becomes the field-return nobody finds quickly.

View the Win-Source product page for DTB123YCHZGT116.

Key Takeaways for Engineers & Buyers

  • Treat 200 mW as the first limit; check whether DTB123YCHZGT116 can stay inside it in SST3.
  • Use the built-in 2.2 kOhms and 10 kOhms only if that bias network matches the drive scheme.
  • Do not plan production around stock of 1; secure reel availability before releasing the BOM.