50V VCEO ceiling, 70mA collector ceiling, 200mW dissipation ceiling, UMT3F package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Rohm Semiconductor |
| Category | Transistors (BJT) - Single, Pre - Biased |
| Package | UMT3F |
| Core function | TRANS PREBIAS NPN 50V UMT3F |
| Key electrical range | Collector Cut-off Current(Max): 500nA; Frequency - Transition: 250MHz; Maximum Current Collector: 70mA; Maximum Power Dissipation: 200mW |
| Reported stock | 3500 pcs reported — confirm on RFQ |
Still, this is a real design-in candidate
And that holds up because the lifecycle picture is unusually clean here: DTC114YUBTL is listed Active in both lifecycle fields, with no conflict to explain away. For a pre-biased transistor, that matters more than a popularity tag, because once the internal resistor values are committed in the schematic, changing devices later is not a casual swap.
Packaging matters too. Reel - TR and 3500 in stock fit normal SMT flow better than bench-build convenience, so DTC114YUBTL makes more sense on a repeatable assembly line than in a one-off hand-loaded build. EU RoHS is compliant.
The ceiling is power, then current, then voltage
The constraint is headroom. The 200mW maximum power dissipation is the first number that limits casual use of DTC114YUBTL as a general-purpose switch, even if the collector rating looks comfortable at a glance. In a UMT3F body, 200mW is a hard ceiling. There is not much thermal slack when the device is held on, and the listing does not include thermal resistance or a derating curve to show how much ambient margin is really available.
Next comes the 70mA maximum collector current. That is a ceiling, not a normal operating point, and it rules out loads that need current margin by default. If your load current sits near that number, the missing thermal data becomes the real blocker, because current by itself does not tell you whether the package can shed the heat under your board conditions.
The 50V VCEO maximum collector-emitter breakdown voltage closes a different question. It places DTC114YUBTL in higher-voltage logic-side switching than the usual low-voltage digital rail parts, but it says nothing about surge behavior or inductive stress because no avalanche or pulse rating is listed.
One more detail matters because this is a pre-biased device rather than a bare transistor. The built-in resistor pair is 10k for R1 and 47k for R2, and that fixes the input-drive behavior up front. If those values match the logic source and turn-off behavior you need, DTC114YUBTL saves parts and placement. If they do not, the integrated network is the reason to pass.
300mV tells you where saturation is actually characterized
300mV is the key figure. The listed maximum VCE(sat) is 300mV @ 250μA, 5mA, and the test point matters as much as the number itself. It gives you one anchored condition for low-current switching, not a blanket promise across the full 70mA collector ceiling.
The rest of the fit picture lines up with that. NPN - Pre-Biased, SMD (SMT), and UMT3F point to dense board-level control work rather than power stages, while the 500nA maximum collector cut-off current helps when off-state leakage matters. The 68 @ 5mA, 5V gain figure is enough to show the intended operating neighborhood. DTC114YUBTL is wrong for designs that need a freely chosen base network or a published high-current saturation map; it is right for compact logic-driven switching where the resistor values are already what you wanted.
The missing review-closers are basic
Some basics are still missing. Pinout, package drawing, thermal resistance, and a derating curve are still needed before layout and thermal signoff, and the electrical listing stops short of those details.
View the Win-Source product page for DTC114YUBTL.
Key Takeaways for Engineers & Buyers
- Keep collector current below the 70mA ceiling; that limit, not hFE, closes the load side first.
- Use the built-in 10k and 47k bias network intentionally; DTC114YUBTL is not a blank small-signal NPN.
- Pull the full datasheet for pinout and thermal data before layout; the listing stops at UMT3F.