100 mA collector ceiling, 350 mW limit, SST3 package, built-in 22 kOhms / 22 kOhms bias network
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Rohm Semiconductor |
| Category | Transistors (BJT) - Single, Pre - Biased |
| Package | Tape & Reel |
| Core function | TRANS PREBIAS NPN 0. |
| Key electrical range | Current - Collector (Ic) (Max): 100 mA; DC Current Gain (hFE) (Min) @ Ic, Vce: 56 @ 5mA, 5V; Frequency - Transition: 250 MHz; Power - Max: 350 mW |
| Reported stock | 4905 pcs reported — confirm on RFQ |
350 mW is the real design limit here
350 mW sets the boundary. More than the 100 mA collector ceiling, it decides whether DTC124ECAHZGT116 belongs in the circuit, because a pre-biased small-signal NPN in SST3 runs out of thermal room before that current figure starts to look comfortable across a wide range of real switching conditions.
The resistor network is the other hard constraint. DTC124ECAHZGT116 fixes R1 at 22 kOhms and R2 at 22 kOhms, so the usual freedom to choose base bias externally is gone; the real design choice is whether that ratio already matches the logic source, the default-off behavior, and the collector load you need to support. The listed 300mV @ 500µA, 10mA Vce(sat) helps frame the part as a low-current switch, but it does not settle behavior at heavier collector current, and the minimum hFE of 56 @ 5mA, 5V still leaves the collector load as the deciding check.
That combination makes the part specific, not broad. Active lifecycle status, EU RoHS compliance, and the Automotive, AEC-Q101 series field support new design-in when the fixed bias network is exactly what the circuit wants.
Those limits point to control paths, not load driving
So the fit is narrow in a useful way. DTC124ECAHZGT116 works in board-level switching where deleting two resistors and locking in a known 22 kOhms / 22 kOhms bias network matters more than having room to tune the base path.
The 100 mA collector ceiling and 350 mW limit keep it out of the general-purpose load-driver bucket. The 300mV @ 500µA, 10mA saturation figure supports small switched loads and logic interfacing, while the 250 MHz transition frequency says it is not a slow transistor by category, though that number alone does not define switching loss or edge behavior in your circuit. SST3 in TO-236-3, SC-59, SOT-23-3 points the same way: dense control sections, not spots where package mass or thermal spread is carrying the design.
Wrong for adjustable bias, right for fixed logic switching
Wrong first: any design that needs adjustable base resistance, shaped turn-on current, or pull-down behavior tuned around a specific controller pin should skip this device.
Right use is simpler. This is a pre-biased NPN for compact switching stages where 22 kOhms on the base path and 22 kOhms from emitter to base are already the values you would have placed around a small transistor anyway. It fits housekeeping control, signal gating, and small on-board switching better than jobs that need the transistor to act like a flexible analog element.
Can you keep a running line on it?
Can you actually keep it flowing through production? The listed stock quantity is 4905, packaging is Tape & Reel, and MSL is 1 (Unlimited), so it drops into normal SMT flow without extra moisture-handling friction.
If this exact pre-biased network is already qualified in your build, buy against running demand instead of assuming 4905 on hand covers every lot split or ramp. The lifecycle is Active, with no conflict in the status fields.
What the listing still does not answer
Rail margin and footprint confidence are still constrained by missing details. Vce breakdown is absent, collector cutoff current is absent, and the pinout or package drawing is not carried here.
View the Win-Source product page for DTC124ECAHZGT116.
Key Takeaways for Engineers & Buyers
- Keep collector load inside the 100 mA ceiling; that number does not buy surge headroom.
- Check that the fixed 22 kOhms R1 and 22 kOhms R2 network matches the logic drive and default-off behavior.
- Use the 300mV @ 500µA, 10mA saturation limit as a low-current switching check, not as a blanket drop for every load.