Rohm Semiconductor DTC124XKAT146 for new design-in

DTC124XKAT146 Rohm Semiconductor product image

50V VCEO ceiling, 50mA collector ceiling, 200mW limit, SMT3 pre-biased NPN with 22k and 47k resistors

Quick Engineering Summary

FieldValue
ManufacturerRohm Semiconductor
CategoryTransistors (BJT) - Single, Pre - Biased
PackageSMT3
Core functionTRANS PREBIAS NPN 50V SMT3
Key electrical rangeCollector Cut-off Current(Max): 500nA; Frequency - Transition: 250MHz; Maximum Current Collector: 50mA; Maximum Power Dissipation: 200mW
Reported stock3000 pcs reported — confirm on RFQ

Active part, but the resistor network decides the fit

Use it.

DTC124XKAT146 is an Active pre-biased NPN, so no lifecycle conflict blocks a new design. The real question is simpler: do the built-in resistors fit the drive scheme you already have?

Here, the fixed network is the whole story. R1 is 22k and R2 is 47k, both inside the part, so it fits circuits that want that biasing from the start: direct logic drive, simple level shifting, or small-signal switching where removing external bias parts helps keep placement tight in SMT3. If your circuit needs a different base current path, stop there. The part is wrong before the 50V VCEO ceiling or 50mA collector ceiling even matter.

The 200mW maximum power dissipation is a ceiling, not an operating point, and in a tiny surface-mount body it sets expectations quickly. This is a housekeeping transistor, not a load driver. EU RoHS is compliant.

50V is the rail limit, not the use case

50V is the hard ceiling. It settles the collector-emitter voltage question for low-voltage rails and small control nodes, but it says nothing about switching loss, avalanche behavior, or transient tolerance beyond that breakdown limit.

And the current rating is only half the story

And that leaves current. The 50mA maximum collector current marks the point where DTC124XKAT146 stops looking like a small-signal switch and starts looking like the wrong transistor.

Pair that with the 300mV maximum VCE(sat) at 500µA, 10mA and the message is clear: the listing gives one useful saturation point for low-current switching loss, but not a full curve for behavior as current moves toward the 50mA ceiling.

Leakage is controlled on paper. The 500nA maximum collector cut-off current helps when the off-state node cannot tolerate much drift, and the 68 minimum hFE at 5mA, 5V shows gain is characterized in the small-signal region rather than near the current limit. The 250MHz transition frequency points to a fast small-transistor core, but without switching waveforms it does not settle a pulse-edge or storage-time decision.

Can you keep a running line on DTC124XKAT146?

Can you actually keep it on a running line? Yes, if you buy the form you plan to place.

Packaging is Reel - TR, stock is 3000, and that lines up with automated SMT use rather than bench builds or hand-loaded service stock.

DTC124XKAT146 makes sense as a running-line choice when the internal 22k and 47k values are already qualified in the circuit. If those resistor values are still under debate, inventory will not rescue the bias choice.

What the listing still does not answer

Wrong for power switching. Right for compact pre-biased control stages.

What is still missing is concrete: pinout confirmation for the SMT3 body, a package drawing, thermal resistance, and switching data such as storage or rise and fall behavior. DTC124XKAT146 also lacks a fuller saturation or forward-drive curve beyond the single 300mV @ 500µA, 10mA point. Those gaps matter more than another line of description.

View the Win-Source product page for DTC124XKAT146.

Key Takeaways for Engineers & Buyers

  • Keep collector stress below the 50V VCEO ceiling; that number closes rail compatibility, not switching behavior.
  • Check base-drive math against the built-in 22k R1 and 47k R2 before locking the logic interface.
  • Buy on reel while stock shows 3000 if DTC124XKAT146 is going straight to SMT placement.