15V VCEO ceiling, 600mA collector limit, 200mW dissipation ceiling, SMT3 pre-biased NPN

Quick Engineering Summary

FieldValue
ManufacturerRohm Semiconductor
CategoryTransistors (BJT) - Single, Pre - Biased
PackageSMT3
Core functionTRANS PREBIAS NPN 15V 0.
Key electrical rangeCollector Cut-off Current(Max): 500nA (ICBO); Frequency - Transition: 200MHz; Maximum Current Collector: 600mA; Maximum Power Dissipation: 200mW
Reported stock1880 pcs reported — confirm on RFQ

Can you still put this on a new BOM?

Can I use it on a new BOM? Probably not.

DTC314TKT146 carries the awkward combination of Active lifecycle status and a separate Not For New Designs flag, so the safe call is sustaining use only. That conflict matters more than the small-signal specs because it decides whether you spend engineering time qualifying a fresh footprint or keep the device confined to existing production.

The rest of the commercial picture is workable, not reassuring. Stock is listed at 1880 and packaging is Reel - TR, so it can support a running line if your feeder setup already expects tape-and-reel. EU RoHS is compliant. Active should not be read as clearance for a clean-sheet design when the status field says otherwise.

The weak point is power, not collector current

Power is the weak point first.

The 200mW maximum power dissipation is the first ceiling to respect, and it closes sooner than the 600mA maximum collector current suggests at a glance. Those numbers do not grant the same freedom. The 600mA figure marks an absolute collector-current limit; it does not say the device can remain there comfortably under your switching loss and ambient conditions, especially when thermal resistance and a derating curve are not listed.

After that, the 15V VCEO maximum sets the rail boundary. It is a breakdown ceiling, not a working target, so DTC314TKT146 belongs on low-voltage nodes with real margin below 15V, not on rails that brush that limit during startup or fault events. The listed 80mV max VCE(sat) at 2.5mA, 50mA is useful, but only at that stated corner. It shows the device can pull low with little drop at 50mA collector current under 2.5mA drive; it does not describe the drop near the 600mA ceiling.

One more detail matters because this is a pre-biased transistor, not a bare BJT. The built-in R1 is 10k, and the listing says only R1 is included. That simplifies a logic-drive stage when the bias network was meant to be internal, but it also locks you into the vendor's input resistor choice instead of tuning base drive externally.

It fits simple low-voltage switching, not thermal guesswork

Use it narrowly.

The appeal here is integration: an NPN pre-biased transistor in SMT3, surface mount, with only R1 included at 10k. That points to compact board-level switching and interface duties where saving one external resistor matters more than extracting every last milliamp from a discrete stage.

The listed hFE minimum of 100 at 50mA, 5V and the 200MHz transition frequency support that reading. This is a small-signal switching part, not a power transistor hiding in a small package, and the rest of the numbers keep reinforcing that boundary.

The trap is assuming the package and the 600mA headline current make it broadly interchangeable with any small SOT-23 switch transistor. They don't. DTC314TKT146 is boxed in by the 15V collector-emitter breakdown ceiling, the 200mW dissipation ceiling, and the fixed 10k base resistor, so a design that needs a chosen base network, more voltage headroom, or confidence well above the 50mA saturation test point already has enough information to stop here.

Leakage is at least bounded on paper: 500nA ICBO max. That helps for off-state housekeeping paths, but it does not fix a design that is short on voltage margin or thermal margin.

The missing curves are the real review blocker

1880 pieces on hand matters only after the electrical gaps are closed. The listing does not give thermal resistance, a derating curve, pinout, or a package drawing.

View the Win-Source product page for DTC314TKT146.

Key Takeaways for Engineers & Buyers

  • Hold DTC314TKT146 to rails that stay inside the 15V VCEO ceiling.
  • Check load current against both the 600mA collector limit and the 200mW dissipation ceiling.
  • Buy on reel only if TR packaging fits the line setup; stock shown is 1880.