50V VCEO ceiling, 500mA collector ceiling, 200mW dissipation ceiling, SMT3 pre-biased NPN with 1k and 10k resistors
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Rohm Semiconductor |
| Category | Transistors (BJT) - Single, Pre - Biased |
| Package | SMT3 |
| Core function | TRANS PREBIAS NPN 50V 0. |
| Key electrical range | Collector Cut-off Current(Max): 500nA; Frequency - Transition: 200MHz; Maximum Current Collector: 500mA; Maximum Power Dissipation: 200mW |
| Reported stock | 60000 pcs reported — confirm on RFQ |
Can you design DTD113ZKT146 in now?
Can you use this part in a new board today? Yes, if the built-in resistor network is the one your circuit already wants. The listing shows an Active lifecycle, reel packaging, and 60000 in stock, so this is a live design-in option rather than a sustaining-only choice.
What matters is where the limits actually bite. The 50V VCEO figure is a collector-emitter breakdown ceiling, so the rail has to stay below it. The 500mA collector current is also a ceiling, not a normal operating point, and the 200mW power dissipation ceiling is the tighter practical limit in a small SMT3 device. Put together, those numbers say the same thing in a more useful way: the current headline looks generous, but heat will decide the real operating window long before the raw current ceiling does.
The other commitment is electrical, not mechanical. DTD113ZKT146 fixes R1 at 1k and R2 at 10k, so base bias and turn-off behavior are part of the package choice. If your original network expected different values, this part is not a neutral swap. It's a circuit decision.
The resistor network is the real commitment
It is. DTD113ZKT146 fits cleanly only when the built-in 1k and 10k values already suit the drive source and the off-state behavior you want.
The ceilings point to low-power switching, not brute drive
The constraint is 200mW. That dissipation ceiling keeps DTD113ZKT146 in low-power board-level switching even with a 500mA collector current ceiling and a 50V breakdown ceiling.
The listed 300mV max VCE(sat) at 2.5mA, 50mA is useful because it ties the saturation claim to a stated test point. It supports use as a small load switch around that condition, but it does not describe saturation near the 500mA ceiling. The 500nA collector cut-off current max helps in standby-sensitive paths, and the 200MHz transition frequency says the device is not unusually slow. Neither one answers the thermal question. The fit is compact logic-driven switching, level shifting, and bias-controlled on/off functions where the integrated resistors remove two externals and the dissipation ceiling stays in view.
50V is enough rail margin, but the datasheet gaps are real
50V is the decisive ceiling. It clears many low-voltage control rails, but it does not settle avalanche behavior, pulse stress, or thermal margin in fault cases.
The missing details are concrete. No pinout or package drawing appears here, even though the package is identified as SMT3 and the listing also names TO-236-3, SC-59, and SOT-23-3, so footprint confirmation remains open. No thermal resistance figure is given, so the 200mW ceiling cannot be tied to ambient headroom. No derating curve is listed either, which leaves temperature headroom unresolved. There is also no pulsed current or surge figure, so DTD113ZKT146 should not be assumed tolerant of startup or fault spikes just because 500mA appears in the listing.
View the Win-Source product page for DTD113ZKT146.
Key Takeaways for Engineers & Buyers
- Check that the built-in 1k R1 and 10k R2 match the logic-drive network before freezing the schematic.
- Keep collector load inside the 200mW dissipation ceiling; the 500mA figure does not settle thermal headroom.
- Book reel quantity against the 60000 stock if DTD113ZKT146 is going onto a running build.