113 units, bulk packaging, shortage status, and unresolved RoHS drive this connector housing decision.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TE Connectivity |
| Category | Rectangular Connector Housings |
| Package | Bulk |
| Core function | DTM06-2S AND WEG ONLY |
| Key electrical range | Supply and Demand Status: Shortage |
| Reported stock | 113 pcs reported — confirm on RFQ |
113 units is the number that changes the decision
113 units is not a runway for a fresh program when the same record also carries a Shortage flag. That combination pushes DTM06-2S-KIT out of comfortable new design-in and into controlled sustaining use.
Lifecycle is Unknown, not obsolete. Pair that with Shortage and the problem shows up before fit ever does, because a connector housing only helps if the exact line item keeps moving through production without stop-start buys or last-minute BOM exceptions. The bulk package says loose-piece purchasing, not a reel-driven assembly assumption, but it does nothing for continuity. Keep DTM06-2S-KIT on existing production where the mating system is already fixed, and do not let it become the default on a new platform unless the supply picture changes. The RoHS fields also conflict, so EU RoHS is still unsettled here.
Wrong for spec-closed programs, fine for known harness builds
Wrong for any program that needs a settled compliance answer at release. The record says both RoHS Compliant and RoHS Non-Compliant, and that alone can stall approval in regulated shipments or any customer flow that expects the connector housing status to be unambiguous before first article.
DTM06-2S-KIT fits a narrower case: a known rectangular connector housing need already designed around this exact item, where bulk packaging is acceptable and the description "DTM06-2S AND WEG ONLY" matches the build intent. The category tells you what it is, but not enough to stretch it into adjacent connector decisions. There is no contact count field beyond the part identifier, no drawing, and no dimensional detail here, so this page cannot close mating, panel, or cavity-fit questions.
15 and 113 don’t tell the same supply story
15 appears in the row data, while 113 appears as stock quantity. That mismatch is enough to keep DTM06-2S-KIT on a controlled buy tied to actual demand, not forecast optimism.
The real gap is mechanical, not electrical
Missing fit data is the constraint. DTM06-2S-KIT is a connector housing, yet the record gives no drawing, no pin or cavity layout, no dimensions, and no mating-part detail beyond the brief description.
Those are the items that would actually close the review. Without them, you cannot confirm envelope, retention features, or whether the housing lands cleanly in the intended interconnect stack. There are no electrical ceilings to interpret on this page, so the missing mechanical definition is the whole story.
View the Win-Source product page for DTM06-2S-KIT.
Key Takeaways for Engineers & Buyers
- Freeze DTM06-2S-KIT to existing production until lifecycle moves off Unknown.
- Match your build plan to the listed 113 units before releasing DTM06-2S-KIT.
- Resolve the RoHS Compliant versus RoHS Non-Compliant conflict before any regulated shipment.
