Littelfuse Inc. DUR60120W for new design-in

DUR60120W Littelfuse Inc. product image

1200 V reverse ceiling, 60 A average rectified ceiling, TO-247AC through-hole, -55°C to 150°C junction

Quick Engineering Summary

FieldValue
ManufacturerLittelfuse Inc.
CategoryDiodes, Rectifiers - Single
PackageTO-247-2
Core functionDIODE STANDARD 1200V 60A TO247AC
Key electrical rangeCurrent - Average Rectified (Io): 60A; Current - Reverse Leakage @ Vr: 650 µA @ 1200 V; Operating Temperature - Junction: -55°C ~ 150°C; Supply and Demand Status: Normal
Reported stock26042 pcs reported — confirm on RFQ

Not for low-loss rails; viable on high-voltage rectification

Wrong for low-loss rails. The listed forward drop is 3.5 V @ 60 A, and that ceiling at a stated current point tells you the conduction budget can get expensive before the 60 A average rectified ceiling becomes the limiting factor.

It fits better in high-voltage rectification that truly needs the 1200 V reverse ceiling and can live in a through-hole TO-247-2 body. Active lifecycle, Normal supply status, and EU RoHS support new design-in rather than sustaining-only work.

1200 V is the number that decides the rail

1200 V decides the rail. It is a reverse ceiling, not a working setpoint, and it answers only whether DUR60120W belongs on a bus that needs that much blocking margin.

The 100 ns trr is the other quick filter, but the commutation picture still needs the rest of the switching data.

The real constraint is heat, not package count

Heat is the constraint the numbers create. A 60 A average rectified ceiling looks generous until it sits beside the listed 3.5 V @ 60 A forward-drop ceiling, because that pairing is the warning sign: conduction loss can dominate the design well before the paper current rating does.

That is why the TO-247-2 and TO-247AC callout matters more than the package name alone suggests. Through-hole power hardware works when the design already expects mechanical fastening, leaded assembly, and a real heat path off the body, but it is a poor match for dense low-profile stages where package height and mounting style are the first mechanical conflict. In practice, DUR60120W belongs in high-voltage, board-mounted power conversion where a discrete rectifier with a substantial thermal path is acceptable, and it does not belong in compact layouts that need surface-mount assembly or in rails where the forward-drop ceiling would consume too much of the loss budget.

The junction range of -55°C to 150°C is also a limit band, not permission to run hot. It says the silicon is specified across that span, while ambient headroom still depends on thermal resistance and derating information that is not listed here.

Can you keep a running line on it?

Can you actually get it? With 26042 pieces listed, in Tube, the practical answer is yes for a running line that already accepts through-hole handling.

Tube packaging is not a footnote here; it affects feeder strategy and line setup in a way reel parts do not. If DUR60120W is going into a fresh build, reserve stock against the build plan instead of assuming spot availability will stay this comfortable.

What the listing still doesn't answer

100 ns trr is useful, but it is not enough to finish the switching argument by itself. Junction capacitance is absent, so commutation behavior around that figure is still incomplete, and thermal resistance is absent, so the jump from 3.5 V @ 60 A to an actual heatsink or copper plan cannot be made here.

IFSM is also absent, leaving startup and fault-pulse tolerance open. A package drawing and pinout are not shown either, which matters because TO-247-2 and TO-247AC identify the family, not the exact mechanical implementation you will release to layout for DUR60120W.

View the Win-Source product page for DUR60120W.

Key Takeaways for Engineers & Buyers

  • Hold the bus against the 1200 V reverse ceiling; that number does not settle surge behavior.
  • Budget conduction loss around the 3.5 V @ 60 A forward-drop ceiling before committing TO-247AC thermal hardware.
  • Use the 100 ns trr in the commutation check, then pull junction capacitance and thermal resistance from the datasheet.