600 V reverse ceiling, 10 A average rectified limit, 32 ns trr, isolated ITO-220AC through-hole package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Littelfuse Inc. |
| Category | Diodes, Rectifiers - Single |
| Package | TO-220-2 Full Pack, Isolated Tab |
| Core function | DIODE STANDARD 600V 10A ITO220AC |
| Key electrical range | Current - Average Rectified (Io): 10A; Current - Reverse Leakage @ Vr: 10 µA @ 600 V; Operating Temperature - Junction: -55°C ~ 150°C; Supply and Demand Status: Normal |
| Reported stock | 11690 pcs reported — confirm on RFQ |
600 V makes this a real mains-side rectifier option
600 V is what puts this device in the conversation for new designs. With Active lifecycle status, Normal supply status, and stock listed at 11690, there is no supply-side reason to avoid it when a single through-hole rectifier has to block a high reverse rail.
That number is only the start. The 600 V reverse rating sets the rail class; it does not answer surge survival, avalanche behavior, or thermal headroom. For sustaining builds and fresh layouts alike, DURF1060 is available now, and the isolated tab plus EU RoHS compliance clear two common mechanical and compliance hurdles.
The real constraint is heat, not just current
Heat is the constraint these numbers create. The listing gives 10 A average rectified current and 2.2 V maximum forward drop at 10 A, so the fit is not decided by current alone; it comes down to how much loss the thermal path can carry in a TO-220-2 Full Pack, Isolated Tab body.
That package helps insulation and mounting simplicity, but it usually gives up thermal efficiency versus a bare-tab approach, and this listing does not include the thermal resistance values that would settle the trade. The -55°C to 150°C junction range is a ceiling band, not a target.
32 ns is why DURF1060 belongs in faster rectifier jobs
32 ns is the decisive dynamic figure here. It places DURF1060 in the fast-recovery camp, and the separate speed line supports that with Fast Recovery <= 500ns, > 200mA (Io), so this is not the slow mains-frequency rectifier you drop in by habit when switching edges and commutation losses start driving the result.
That matters in two directions. First, DURF1060 fits offline power stages, freewheel paths, and secondary-side rectification where reverse recovery can punish efficiency or switching stress long before the 600 V reverse ceiling is approached. Second, it is still a standard technology diode, not a free pass for every high-frequency slot.
The 32 ns figure helps with recovery-related loss and noise, but the listing does not include junction capacitance, and that missing number can decide whether ringing stays manageable or turns ugly in the actual layout. The leakage line also reads better as a boundary than a comfort statement: 10 µA at 600 V says the reverse current ceiling is controlled at the full rated reverse voltage, but only at that stated condition. It does not show how leakage shifts across the -55°C to 150°C junction range, and that missing curve can separate a bench pass from a hot-box surprise.
The missing thermal and parasitic data still matter
The weak point is missing closure data, not availability. DURF1060 still needs junction capacitance, thermal resistance, and a package drawing or pinout from the datasheet before layout or thermal work is closed.
View the Win-Source product page for DURF1060.
Key Takeaways for Engineers & Buyers
- Hold the reverse rail below the 600 V ceiling; that number does not settle surge behavior.
- Budget conduction loss around the 2.2 V at 10 A forward-drop limit before committing the isolated TO-220-2 footprint.
- Use the 32 ns trr only where fast recovery matters; pull the junction capacitance and thermal data from the datasheet first.