DUXL01D Honeywell product image

0.04PSI differential range, 3.61PSI ceiling, 3V to 8V bridge supply, 4-SIP through-hole package

Quick Engineering Summary

FieldValue
ManufacturerHoneywell
CategoryPressure Sensors, Transducers
PackageTube
Core functionSENSOR 0.
Key electrical rangeOutput: 0 mV ~ 6 mV (4.5V); Output Type: Wheatstone Bridge; Temperature Range - Operating: -25°C ~ 85°C; Voltage - Supply: 3V ~ 8V
Reported stock1 pcs reported — confirm on RFQ

Sustaining only; don’t start here

Don’t design this in.

DUXL01D is discontinued, and both lifecycle fields say so. There is no ambiguity. That settles the new-design question right away: keep it to existing production only, and move quickly if you still need units because listed stock is 1. EU RoHS is present, and MSL 1 (Unlimited) removes a storage-handling concern, but neither changes the lifecycle risk.

3.61PSI is the number that keeps you honest

3.61PSI (24.92kPa) is the ceiling.

The operating point named here is 0.04PSI (0.25kPa) differential, which puts DUXL01D in very low-pressure measurement where small changes matter and overpressure control matters more. Miss that distinction and you are no longer talking about a little accuracy loss; you are pushing the sensing element against the only pressure limit the listing gives.

The other figure that shapes interface fit is the output: 0 mV ~ 6 mV at 4.5V, from a Wheatstone bridge. That tells you what kind of signal chain you are dealing with. It is a raw low-level bridge output, not a conditioned voltage or digital sensor, and the 3V ~ 8V supply range gives some flexibility for bridge excitation while leaving downstream amplification, offset handling, and noise margin unanswered here.

The constraint is mechanical as much as electrical

The constraint is packaging.

This is a through-hole 4-SIP module with PC pins and dual male 0.08" (2.03mm) barbed ports. It suits a board-level pneumatic assembly, not a loose hose-in-line build.

0.04PSI range is useful, but the missing curves still matter

0.04PSI (0.25kPa) is the reason to look at it.

That range points DUXL01D at very small differential pressure, and the listed ±0.5% accuracy is the clearest sign here that the sensor is meant to resolve those small changes rather than tolerate rough pressure handling. Add the -25°C ~ 85°C operating range and it fits ordinary industrial or instrument environments, but those numbers still do not finish the analog or mechanical picture.

They don’t. The listing does not give a pinout, so board connectivity still depends on the datasheet. It does not give a package drawing, leaving footprint and keepout open despite the 4-SIP description. It does not give a transfer curve beyond 0 mV ~ 6 mV at 4.5V, so offset behavior across pressure and temperature remains unknown. Pressure media compatibility is also absent, and that is a real fit question for any differential sensor with dual barbed ports.

So the classification is easy, while reuse is not: the range, pressure ceiling, and package tell you where DUXL01D belongs, but the missing mechanical and analog details are exactly what slow a re-qualification decision.

View the Win-Source product page for DUXL01D.

Key Takeaways for Engineers & Buyers

  • Lock any DUXL01D demand to existing production only; listed stock is 1.
  • Check that your excitation rail stays within 3V to 8V before keeping DUXL01D on a board spin.
  • Confirm the pneumatic hookup matches the dual 0.08" (2.03mm) barbed ports and 4-SIP footprint.