Honeywell DUXL05D discontinued, sustaining use only

DUXL05D Honeywell product image

0.18PSI differential range, 3.61PSI ceiling, 3V to 8V supply, 4-SIP board-mount package

Quick Engineering Summary

FieldValue
ManufacturerHoneywell
CategoryPressure Sensors, Transducers
PackageTube
Core functionSENSOR 0.
Key electrical rangeOutput: 0 mV ~ 22.5 mV (4.5V); Output Type: Wheatstone Bridge; Temperature Range - Operating: -25°C ~ 85°C; Voltage - Supply: 3V ~ 8V
Reported stock1 pcs reported — confirm on RFQ

3.61PSI is the hard stop, and the lifecycle ends the argument

3.61PSI (24.92kPa) is the ceiling. More decisive still, DUXL05D is discontinued, so the answer for new design-in is no. If you already ship with it, this is sustaining-only territory, and listed stock of 1 leaves little room to stretch.

The rest of the listing points to a narrow low-pressure role, not a reason to ignore the lifecycle problem. Operating pressure is 0.18PSI (1.25kPa), pressure type is differential, and the package is a 4-SIP board-mount module with PC pins and dual barbed ports. EU RoHS is compliant, and MSL 1 (Unlimited) is easy enough to accommodate, but neither changes the decision.

That low range is useful only if your analog front end is ready

So the electrical side has to carry its weight. The output is 0 mV ~ 22.5 mV (4.5V) from a Wheatstone bridge, with a 3V ~ 8V supply range. That is a small signal, and it puts the burden on low-noise amplification and offset control more than on the sensor itself.

Accuracy is listed at ±0.5%, but that matters only in the context of the 0.18PSI operating pressure and the bridge output span. Feed it into a casual MCU ADC path and the front end becomes the weak link long before the sensor does. The listing also stops short of drift, stability, and calibration method, so those details remain open.

Wrong for broad-range pressure work, right for tiny differential signals

Not for high-pressure lines. Not for applications that need a buffered voltage output.

What it is for is very small differential pressure measurement, and the listing is clear about that: 0.18PSI (1.25kPa) operating pressure, Wheatstone bridge output, and dual 0.08" (2.03mm) barbed ports on a board-mount sensor. That combination suits pneumatic or airflow-style measurement where tubing lands directly on the part and the board carries the conditioning circuit.

The mechanical format matters too. A 4-SIP module with PC pin termination keeps it firmly in through-hole territory, which can work well in serviceable industrial assemblies but fits less naturally on dense mixed-signal boards already built around surface mount. The dual barbed male ports narrow the fit further; if the enclosure, tubing, or assembly flow does not want that porting, the part is out before the analog discussion even starts.

Temperature range is -25°C ~ 85°C. Useful, but limited. It defines the operating window and nothing more, so it does not answer error across temperature or quantified thermal drift for harsher programs.

1 piece on hand means buy only to bridge an existing build

1 piece is the constraint that turns a lifecycle warning into a production problem. DUXL05D is already discontinued, standard package is 5, and the open-market fake threat is listed at 50 pct.

That is not just a sourcing annoyance. It is line-stoppage risk if you wait until the last board fails. Use remaining stock only to cover existing production or service demand, freeze any new BOM activity around DUXL05D, and keep any purchased lot tightly controlled because discontinuation plus minimal availability is exactly where bad material enters the build.

The missing curves are the real blocker

Weak point first: the listing does not give pinout, package drawing, pressure transfer function, or temperature error behavior. For DUXL05D, those gaps block integration more than the basic headline specs do.

View the Win-Source product page for DUXL05D.

Key Takeaways for Engineers & Buyers

  • Lock the bridge excitation inside 3V to 8V; the output is listed as 0 mV to 22.5 mV at 4.5V.
  • Treat 3.61PSI as the pressure ceiling, not the working point; the intended operating pressure is 0.18PSI differential.
  • Reserve DUXL05D only for existing builds; stock is 1 and lifecycle is Discontinued.