3 to 1 shrink, 2.000" supplied ID, 0.800" recovered ID, -40°C to 110°C operating, 80°C shrink
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TE Connectivity |
| Category | Heat Shrink Tubing |
| Package | Bulk |
| Core function | HEATSHRINK 2\\ |
| Key electrical range | Shrink Temperature: 80°C; Storage/Refrigeration Temperature: 32°F ~ 95°F (0°C ~ 35°C); Temperature Range - Operating: -40°C ~ 110°C |
| Reported stock | 7440 pcs reported — confirm on RFQ |
Can you put this on a new harness build?
Will it fit the build and survive the environment? If that answer is yes, this is a credible new-design choice. DWP-125-2-0-STK is listed as Active, with dimensions that drive the decision: 2.000" (50.80mm) supplied ID, 0.800" (20.32mm) recovered ID, and 0.100" (2.54mm) recovered wall thickness.
Those numbers set the real limits. The tube has to pass over the largest connector or splice before recovery, then finish with enough wall after shrink to do the job. A 3 to 1 shrinkage ratio gives you a wider fit window, but it doesn't settle the whole question, because the recovered size and wall still determine the finished result on the harness.
The construction points to heavier-duty cable work, not cosmetic sleeving. Adhesive lined, flame retardant, flexible polyolefin (PO), and black color all line up with sealed cable transitions, harness splices, and bundle breakouts. The listed operating range is -40°C to 110°C, so 110°C is the ceiling, and that keeps it in ordinary industrial and equipment wiring rather than hotter zones. EU RoHS is clear, and 7440 pieces in Bulk packaging make it practical for production, not just a trial lot.
80°C is the process gate
80°C sets the process gate. It is the listed shrink temperature, so recovery starts there, but the listing does not give recovery time, heat profile, or how evenly the adhesive flows through a dense splice pack.
This is for sealed bulk, not fine finish work
Good fit.
This tubing belongs where cable management is doing mechanical and environmental work, not just appearance or labeling. The 0.100" (2.54mm) recovered wall thickness and 3 to 1 ratio make sense for harness splices, cable exits, and bundle transitions.
It is a poor choice when the assembly needs a very low-profile recovered sleeve, frequent service removal, or a temperature envelope above 110°C. The 0.800" (20.32mm) recovered ID is also a hard floor; if the final bundle needs a much smaller sleeve, this one stays too large.
The missing drawing matters more than the stock count
The weak point is documentation depth. Availability is fine.
Bulk packaging, a standard package of 80, and 7440 in stock support a real build, but the listing still leaves out details that close a harness release. Length appears as 4.00' (1.22m), yet there is no drawing here to confirm cut form, tolerances, or how that length is presented in bulk.
The listing also omits recovered-dimension tolerance, adhesive performance detail, and any shrink profile beyond the single 80°C trigger. For a part chosen on fit and process yield, those gaps can stop the line at first article.
View the Win-Source product page for DWP-125-2-0-STK.
Key Takeaways for Engineers & Buyers
- Check the harness or splice against 2.000" supplied ID and 0.800" recovered ID before releasing DWP-125-2-0-STK.
- Store DWP-125-2-0-STK at 32°F ~ 95°F (0°C ~ 35°C) and watch the 60 Months shelf life on adhesive-lined stock.
- Buy in multiples of 80 where possible; listed stock is 7440 and package is Bulk.