50-position, 2-row right-angle panel-mount through-hole receptacle with M2.6 shell and board lock
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Hirose Electric Co Ltd |
| Category | D - Shaped Connectors - Centronics |
| Package | Tray |
| Core function | CONN MINI HD RCPT 50P R/A SOLDER |
| Key electrical range | Supply and Demand Status: Shortage |
| Reported stock | 755 pcs reported — confirm on RFQ |
Shortage is the weak point; the form factor is the reason to use it
Start with the drawback: the line is flagged Shortage, so it does not belong in a build plan with no schedule slack. The case for using it is mechanical fit. This is an Active 50-position, 2-row miniature high-density receptacle with right-angle, through-hole, panel-mount construction, plus board lock and an M2.6 housing/shell feature.
That combination answers the real design-in question. Use it when the enclosure and PCB need to share retention duty, because the board lock supports the board side while the panel-mount shell and M2.6 feature point to mechanical anchoring beyond solder joints carrying insertion load. EU RoHS compliance is clear. New design-in makes sense when the interface already matches and the shortage can be covered now.
Wrong for floating cable ends, right for fixed panel-to-board I/O
Not for floating cable ends. This is a receptacle with an explicit mounting scheme: panel mount, through hole, right angle. If the product needs vertical entry, surface mount, or a connector that takes mating stress through solder terminations alone, this one is out.
Where it fits is fixed equipment I/O that brings a cable interface through a chassis wall and then turns onto the PCB. The 50 positions and 2 rows set the routing density and mating format, while the miniature high-density family and outer shroud contacts style mean the mating geometry has to match exactly across the full interface, not just at a few key dimensions.
Retention is the other detail that changes the decision. Board lock is not decorative on a right-angle soldered connector; it signals that the part is meant to resist handling and insertion forces with more than solder alone. Gold contact finish helps, but without finish thickness it does not settle wear-life or fretting questions. In short, it belongs in fixed panel-to-board I/O when panel alignment, right-angle escape, and a 50-position high-density interface are already defined.
And the missing mechanical detail still matters
And that is where the listing stops. The remaining gaps are concrete: pinout or contact numbering, the mechanical drawing, and exact contact finish thickness. Without them, you can't lock the land pattern, panel cutout, or expected mating durability from this page alone.
755 pieces means buy for the build, not for theory
755 pieces is enough to matter and not enough to relax. The constraint is the combination of listed stock and a Shortage flag. Tray packaging is normal for this style and helps handling, but it does not change continuity if demand moves past what is on hand.
Act on supply, not lifecycle. If this is already the right mechanical interface, place coverage for the scheduled build quantity now and keep it off speculative future variants until the supply condition clears.
View the Win-Source product page for DX10G1M-50SE(50).
Key Takeaways for Engineers & Buyers
- Match the mating interface to 50 positions and 2 rows before releasing DX10G1M-50SE(50) to layout.
- Reserve panel hardware for the Housing/Shell (M2.6) flange on DX10G1M-50SE(50).
- Buy early; stock is 755 and the line is flagged Shortage.