20dBm ceiling, 50MHz to 870MHz span, 1.5dB insertion loss, 0603 package, discontinued
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Murata Electronics North America |
| Category | RF Directional Coupler |
| Package | 0603 (1608 Metric) |
| Core function | RF DIR COUPLER 50MHZ-870MHZ 0603 |
| Key electrical range | Frequency: 50MHz ~ 870MHz; Power - Max: 20dBm; Supply and Demand Status: Shortage |
| Reported stock | 2 pcs reported — confirm on RFQ |
Discontinued kills new design-in, despite a usable RF span
The weak point comes first: lifecycle is discontinued, with an EOL flag appearing alongside that status. That ends any case for new design-in.
There is still a reason it stays relevant for sustaining builds. The listed 50MHz to 870MHz range is broad enough for low-band and sub-GHz RF paths, the 0603 package keeps it in the compact passive class, and RoHS compliance does not change the lifecycle risk. Use DXP18CN7515TL only where the build already exists and the exact part still matters.
20dBm is a ceiling, not your working power
20dBm is the listed maximum power. Treat it as a ceiling, then read 1.5dB insertion loss and 20dB isolation as the basic RF tradeoff, with return loss still missing.
Can you actually buy DXP18CN7515TL for a running line?
Can you actually get enough parts to keep a line moving? Probably not.
Stock quantity is 2, and the supply and demand status is Shortage. Tape & Reel is the package format, but presentation is not the problem here. Availability is.
That matters more than it would for a generic passive. DXP18CN7515TL is an RF directional coupler with a defined 50MHz to 870MHz range, 1.5dB insertion loss, and 20dB isolation, so once it sits on a qualified RF path, changing it becomes a circuit decision rather than a simple purchasing swap. A tiny remainder may cover failure analysis or a tightly defined sustaining need, but it does not support a fresh program or even much confidence in ongoing production.
The practical fit is narrow. It belongs on compact RF boards that need a coupler in a 0603 footprint across that sub-GHz span, and it does not belong in a new layout where lifecycle stability matters more than footprint convenience. The 20dBm figure does not rescue that decision, because it is only the listed ceiling.
The missing RF details are the real review blocker
1.5dB is not enough by itself.
The missing details that block a serious RF check are coupling factor, return loss, and pinout or drawing information for board orientation. Coupling factor sets the sampled-port level available to the detector or monitor, return loss sets the mismatch penalty on the main line, and the drawing or pinout determines whether layout preserves the intended directionality in a 0603 body. Without those, this page can place DXP18CN7515TL in a BOM discussion, but it can't finish the RF implementation.
View the Win-Source product page for DXP18CN7515TL.
Key Takeaways for Engineers & Buyers
- Block DXP18CN7515TL from new BOM releases; lifecycle is Discontinued.
- Reserve the 2 pieces only for existing production or failure analysis.
- Check the RF path budget against 1.5dB insertion loss and 20dB isolation before using DXP18CN7515TL.