100 V, 2 A, 900 mW, PowerDI3333-8, -55°C to 175°C junction: the thermal and voltage ceilings decide this one.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Diodes Incorporated |
| Category | Transistors (BJT) - Single |
| Package | Tape & Reel |
| Core function | TRANS NPN 100V 2A POWERDI3 |
| Key electrical range | Current - Collector (Ic) (Max): 2 A; Current - Collector Cutoff (Max): 50nA (ICBO); DC Current Gain (hFE) (Min) @ Ic, Vce: 100 @ 500mA, 2V; Frequency - Transition: 175MHz |
| Reported stock | 728 pcs reported — confirm on RFQ |
The real limit here is heat, not headline current
The constraint is the numbers themselves: 2 A looks comfortable until it meets a 900 mW package ceiling. That is the real filter on DXTN07100BFG-7. It is an Active NPN for new design-in where a 100 V collector-emitter breakdown ceiling fits the rail and where conduction loss stays inside what the PowerDI3333-8 package can actually shed.
The useful number here is Vce(sat). It is listed at 400mV @ 200mA, 2A, which gives you a stated switch-drop point under stated drive and load conditions, but not a full picture of how that drop shifts with current or temperature across the operating range. In practice, that missing detail matters more than the headline 2 A because the thermal budget can close first, especially in a compact surface-mount body where board conditions decide how much of the 900 mW ceiling is really available.
The 100 V breakdown rating also needs to be read as a ceiling, not a target operating rail. It opens the door to higher-voltage low-side work, and it closes the door fast where transients crowd that limit. Short version: usable, but not forgiving.
Not for linear soak or unknown switching edges
Wrong job first: don’t use this part for linear operation where it sits hot for long periods, and don’t use it for fast switching work when capacitance, storage, or recovery behavior sets the loss picture. The listing gives 175MHz transition frequency. Useful, but not enough. It does not replace switching waveforms, reverse-recovery data, or capacitance.
Where the device does make sense is compact discrete control at moderate current when 100 V is the gating requirement and a through-hole power transistor is too large. The minimum hFE of 100 @ 500mA, 2V helps because it shows the base-drive burden is not being hidden at mid-current, though it still does not promise the same gain at 2 A. The -55°C to 175°C operating junction range is broad, which helps environmental fit, but it does not relax the 900 mW ceiling.
Can you keep a running line on it?
Can you buy it without creating a supply headache? Yes, with one clear caveat. Lifecycle is Active across the listed signals, MSL is 1 (Unlimited), packaging is Tape & Reel, and stock is 728, so DXTN07100BFG-7 does not show a lifecycle warning for new builds or sustaining demand.
The exposure is in the market, not the status line. A 42 pct. fake-threat figure is high enough to change sourcing behavior, so keep DXTN07100BFG-7 on franchised or known-traceable channels and stay away from last-minute spot buys if production depends on it. Wettable flank mounting also stands out because it supports inspection-friendly surface-mount assembly when the electrical fit is right.
What the listing still doesn’t answer
And that leaves the real signoff gaps. There is no thermal resistance, so ambient headroom is still open. There is no derating curve, so the 900 mW ceiling cannot be mapped cleanly across board temperature. There is no pinout or package drawing here, so footprint and current-path review still depend on the datasheet.
The switching picture is incomplete too. No junction capacitance, no storage or recovery behavior, and no safe-operating-area view are listed. For a 100 V, 2 A transistor, those are the omissions that can turn a part from fine on paper to hot on the bench.
View the Win-Source product page for DXTN07100BFG-7.
Key Takeaways for Engineers & Buyers
- Keep VCE below the 100 V breakdown ceiling; that number closes rail fit, not switching behavior.
- Budget dissipation from the 400mV @ 200mA, 2A saturation limit against the 900 mW package ceiling.
- Use the 728 on hand for planned builds, not open-market backfill, given the 42 pct. fake-threat flag.